enow.com Web Search

  1. Ads

    related to: 2 ton hvac unit dimensions explained youtube video today

Search results

  1. Results from the WOW.Com Content Network
  2. Ton of refrigeration - Wikipedia

    en.wikipedia.org/wiki/Ton_of_refrigeration

    Just as horsepower and candlepower were intuitive units of measure for people living through the transition from horse to steam power [3] and from flame-based to electric lighting, so was the ton of refrigeration an intuitive unit of measure during a technological change, as the ice trade gradually included growing percentages of artificial ice ...

  3. Dedicated outdoor air system - Wikipedia

    en.wikipedia.org/wiki/Dedicated_outdoor_air_system

    DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...

  4. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  5. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.

  6. Air conditioning - Wikipedia

    en.wikipedia.org/wiki/Air_conditioning

    Air conditioning equipment will reduce the absolute humidity of the air processed by the system if the surface of the evaporator coil is significantly cooler than the dew point of the surrounding air. An air conditioner designed for an occupied space will typically achieve a 30% to 60% relative humidity in the occupied space. [51]

  7. Scroll compressor - Wikipedia

    en.wikipedia.org/wiki/Scroll_compressor

    It is used in air conditioning equipment, as an automobile supercharger (where it is known as a scroll-type supercharger) and as a vacuum pump. Many residential central heat pump and air conditioning systems and a few automotive air conditioning systems employ a scroll compressor instead of the more traditional rotary , reciprocating , and ...

  8. Chilled beam - Wikipedia

    en.wikipedia.org/wiki/Chilled_beam

    A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.

  9. Variable refrigerant flow - Wikipedia

    en.wikipedia.org/wiki/Variable_refrigerant_flow

    Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. [1] Similar to ductless mini-split systems, VRFs use refrigerant as the primary cooling and heating medium, and are usually less complex than conventional chiller-based systems. also known the VRV system really takes it to the next level.

  1. Ads

    related to: 2 ton hvac unit dimensions explained youtube video today