enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Firewall (construction) - Wikipedia

    en.wikipedia.org/wiki/Firewall_(construction)

    A fire barrier wall, or a fire partition, is a fire-rated wall assembly that are not structurally self-sufficient. [ 2 ] Fire barrier walls are typically continuous from an exterior wall to an exterior wall, or from a floor below to a floor or roof above, or from one fire barrier wall to another fire barrier wall, having a fire resistance ...

  3. High-voltage transformer fire barriers - Wikipedia

    en.wikipedia.org/wiki/High-voltage_transformer...

    The primary North American document that deals with outdoor high-voltage transformer fire barriers is NFPA 850. [1] NFPA 850 outlines that outdoor oil-insulated transformers should be separated from adjacent structures and from each other by firewalls, spatial separation, or other approved means for the purpose of limiting the damage and potential spread of fire from a transformer failure.

  4. Fire protection engineering - Wikipedia

    en.wikipedia.org/wiki/Fire_protection_engineering

    The discipline of fire engineering includes, but is not exclusive to: Fire detection – fire alarm systems and brigade call systems; Active fire protection – fire suppression systems; Passive fire protection – fire and smoke barriers, space separation; Smoke control and management; Escape facilities – emergency exits, fire lifts, etc.

  5. Firestop - Wikipedia

    en.wikipedia.org/wiki/Firestop

    A firestop or fire-stopping is a form of passive fire protection that is used to seal around openings and between joints in a fire-resistance-rated wall or floor assembly. Firestops are designed to maintain the fire-resistance rating of a wall or floor assembly intended to impede the spread of fire and smoke.

  6. Fire door - Wikipedia

    en.wikipedia.org/wiki/Fire_door

    A fire door is a door with a fire-resistance rating (sometimes referred to as a fire protection rating for closures) used as part of a passive fire protection system to reduce the spread of fire and smoke between separate compartments of a structure and to enable safe egress from a building or structure or ship.

  7. Penetration (firestop) - Wikipedia

    en.wikipedia.org/wiki/Penetration_(firestop)

    A penetration, in firestopping, is an opening, such as one created by the use of a cast-in-place sleeve, in a wall or floor assembly required to have a fire-resistance rating, for the purpose of accommodating the passage of a mechanical, electrical, or structural penetrant. [1] The penetration may or may not contain a firestop system.

  8. Fire blocking - Wikipedia

    en.wikipedia.org/wiki/Fire_blocking

    Fire blocking may also serve as bridging between framing elements, stiffening them against lateral buckling. [4] [5] Fire blocking or firestopping terminology was used interchangeably in code language from its first mention in the 1905 National Building Code (NBC), and requirements were expanded in the 1927 Uniform Building Code (UBC). Building ...

  9. Passive fire protection - Wikipedia

    en.wikipedia.org/wiki/Passive_fire_protection

    Fire-resistance rated wall assembly with fire door, cable tray penetration and intumescent cable coating. Passive fire protection (PFP) is components or systems of a building or structure that slows or impedes the spread of the effects of fire or smoke without system activation, and usually without movement. [1]