enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Highway Addressable Remote Transducer Protocol - Wikipedia

    en.wikipedia.org/wiki/Highway_Addressable_Remote...

    In point-to-point mode the digital signals are overlaid on the 420 mA loop current. Both the 420 mA current and the digital signal are valid signalling protocols between the controller and measuring instrument or final control element. The polling address of the instrument is set to "0". Only one instrument can be put on each instrument ...

  3. Current loop - Wikipedia

    en.wikipedia.org/wiki/Current_loop

    A major application of current loops is the industry de facto standard 420 mA current loop for process control applications, where they are extensively used to carry signals from process instrumentation to proportional–integral–derivative (PID) controllers, supervisory control and data acquisition (SCADA) systems, and programmable logic ...

  4. Signal Chain Solution for 4-mA to 20-mA HART Enabled Field ...

    www.aol.com/2013/03/26/signal-chain-solution-for...

    For premium support please call: 800-290-4726 more ways to reach us

  5. Digital current loop interface - Wikipedia

    en.wikipedia.org/wiki/Digital_current_loop_interface

    A digital current loop uses the absence of current for high (space or break), and the presence of current in the loop for low (mark). [1] This is done to ensure that on normal conditions there is always current flowing and in the event of a line being cut the flow stops indefinitely, immediately raising the alarm of the event usually as the heavy noise of the teleprinter not being synchronized ...

  6. Rogowski coil - Wikipedia

    en.wikipedia.org/wiki/Rogowski_coil

    A Rogowski coil is a toroid of wire used to measure an alternating current I(t) through a cable encircled by the toroid. The picture shows a Rogowski coil encircling a current-carrying cable.

  7. Valve actuator - Wikipedia

    en.wikipedia.org/wiki/Valve_actuator

    The limit switches signal when an end position has been reached. The torque switching measures the torque present in the valve. When exceeding a set limit, this is signaled in the same way. Actuators are often equipped with a remote position transmitter which indicates the valve position as continuous 4-20mA current or voltage signal.

  8. Electrical length - Wikipedia

    en.wikipedia.org/wiki/Electrical_length

    [4]: p.12–14 If the electrical length is much less than one, that is the physical length of a conductor is much shorter than the wavelength, say less than one tenth of the wavelength (< /) it is called electrically short. In this case the voltage and current are approximately constant along the conductor, so it acts as a simple connector ...

  9. Minimum detectable signal - Wikipedia

    en.wikipedia.org/wiki/Minimum_detectable_signal

    A minimum detectable signal is a signal at the input of a system whose power allows it to be detected over the background electronic noise of the detector system. It can alternately be defined as a signal that produces a signal-to-noise ratio of a given value m at the output. In practice, m is usually chosen to be greater than unity.