D LCO or T LCO (diffusing capacity or transfer factor of the lung for carbon monoxide (CO), [1]) is the extent to which oxygen passes from the air sacs of the lungs into the blood. Commonly, it refers to the test used to determine this parameter. It was introduced in 1909. [2]
In addition, gas transport is only diffusion limited in extreme cases, such as for oxygen uptake at very low ambient oxygen or very high pulmonary blood flow. [citation needed] The diffusing capacity does not directly measure the primary cause of hypoxemia, or low blood oxygen, namely mismatch of ventilation to perfusion: [2]
Measurement of the single-breath diffusing capacity for carbon monoxide (DLCO) is a fast and safe tool in the evaluation of both restrictive and obstructive lung disease. [ citation needed ] Bronchodilator responsiveness
People with COPD also exhibit a decrease in diffusing capacity of the lung for carbon monoxide due to decreased surface area in the alveoli, as well as damage to the capillary bed. [112] Testing the peak expiratory flow (the maximum speed of expiration), commonly used in asthma diagnosis, is not sufficient for the diagnosis of COPD. [111]
Hypoxemia refers to insufficient oxygen in the blood. Thus any cause that influences the rate or volume of air entering the lungs (ventilation) or any cause that influences the transfer of air from the lungs to the blood may cause hypoxemia. As well as these respiratory causes, cardiovascular causes such as shunts may also result in hypoxemia.
Diffusing capacity (or DLCO) is the carbon monoxide uptake from a single inspiration in a standard time (usually 10 seconds). During the test the person inhales a test gas mixture that consisting of regular air that includes an inert tracer gas and CO, less than one percent.
Hypoxia can be due to external causes, when the breathing gas is hypoxic, or internal causes, such as reduced effectiveness of gas transfer in the lungs, reduced capacity of the blood to carry oxygen, compromised general or local perfusion, or inability of the affected tissues to extract oxygen from, or metabolically process, an adequate supply ...
Breath carbon monoxide device. Breath carbon monoxide is the level of carbon monoxide in a person's exhalation. It can be measured in a breath carbon monoxide test, generally by using a carbon monoxide breath monitor (breath CO monitor), such as for motivation and education for smoking cessation and also as a clinical aid in assessing carbon monoxide poisoning.