Ads
related to: pressure regulator sizing calculator- Webinars
Learn more about our products by
joining our webinars. Book now!
- Flow regulation
Regulation of the flow
of stormwater
- Flood protection
See all products
and related case studies
- Download drawings
Download brochures, technical
information and more
- Webinars
Search results
Results from the WOW.Com Content Network
The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 scfm when C v = 1.0, 2 psia input).
Diagram symbols for pressure reduction and back pressure regulators. The conceptual difference is mainly in which side the feedback is taken from. A pressure regulator is a valve that controls the pressure of a fluid to a desired value, using negative feedback from the controlled pressure. Regulators are used for gases and liquids, and can be ...
The above equations calculate the steady state mass flow rate for the pressure and temperature existing in the upstream pressure source. If the gas is being released from a closed high-pressure vessel, the above steady state equations may be used to approximate the initial mass flow rate. Subsequently, the mass flow rate decreases during the ...
Orifice plate showing vena contracta. An orifice plate is a thin plate with a hole in it, which is usually placed in a pipe. When a fluid (whether liquid or gaseous) passes through the orifice, its pressure builds up slightly upstream of the orifice [1] but as the fluid is forced to converge to pass through the hole, the velocity increases and the fluid pressure decreases.
For example, a K v calculation of 4.5 m 3 /h would most likely lead to the selection of a valve with a K v = 6.3 m 3 /h. This means the valve is capable of delivering 40% more flow than required. As pressure increases in our variable flow system, our valve will deliver this extra pressure flow.
The regulator is adjusted to control the downstream pressure, which will limit the maximum flow of gas out of the cylinder at the pressure shown by the downstream gauge. For some purposes, such as shielding gas for arc welding, the regulator will also have a flowmeter on the downstream side.
The closed center circuits exist in two basic configurations, normally related to the regulator for the variable pump that supplies the oil: Constant pressure systems (CP), standard. Pump pressure always equals the pressure setting for the pump regulator. This setting must cover the maximum required load pressure.
The regulator ensures that pressure of the gas from the tanks matches the required pressure in the hose. The flow rate is then adjusted by the operator using needle valves on the torch. Accurate flow control with a needle valve relies on a constant inlet pressure. Most regulators have two stages.
Ads
related to: pressure regulator sizing calculator