enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    On the three secondary terminals, the center tap is grounded with a short strap to the transformer case. A split-phase or single-phase three-wire system is a type of single-phase electric power distribution. It is the alternating current (AC) equivalent of the original Edison Machine Works three-wire direct-current system. Its primary advantage ...

  3. Gender of connectors and fasteners - Wikipedia

    en.wikipedia.org/wiki/Gender_of_connectors_and...

    Schematic symbols for male and female connector pins. In electrical and mechanical trades and manufacturing, each half of a pair of mating connectors or fasteners is conventionally designated as male or female, [1] a distinction referred to as its gender. [2] The female connector is generally a receptacle that receives and holds the male connector.

  4. Single-line diagram - Wikipedia

    en.wikipedia.org/wiki/Single-line_diagram

    A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.

  5. High-leg delta - Wikipedia

    en.wikipedia.org/wiki/High-leg_delta

    High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings. Another method (the open delta configuration) requires two transformers.

  6. Substation - Wikipedia

    en.wikipedia.org/wiki/Substation

    The first step in planning a substation layout is the preparation of a one-line diagram, which shows in simplified form the switching and protection arrangement required, as well as the incoming supply lines and outgoing feeders or transmission lines. It is a usual practice by many electrical utilities to prepare one-line diagrams with ...

  7. File:Thermoelectric Generator Diagram.svg - Wikipedia

    en.wikipedia.org/wiki/File:Thermoelectric...

    You are free: to share – to copy, distribute and transmit the work; to remix – to adapt the work; Under the following conditions: attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made.

  8. Camlock (electrical) - Wikipedia

    en.wikipedia.org/wiki/Camlock_(electrical)

    Each camlock connector carries a single phase, pole, or conductor; multiple camlock connectors will be used to make a complete electrical supply or circuit. The most common form is the 16 series, rated at 400 amperes with 105 °C terminations. Also in common use is the 15 series (mini-cam), rated at 150 amperes.

  9. Powerlock - Wikipedia

    en.wikipedia.org/wiki/Powerlock

    Line Source connectors (top) mated with Line Drain connectors (bottom). Panel Drain (female) connectors, for feeding power in to a portable distribution cabinet Powerlock is a range of single-pole electrical connectors used for temporary high-current, low-voltage (up to 1000 V AC) applications, [ 2 ] similar to but considered safer than camlock ...