enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Transformer oil testing - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil_testing

    The transformer oil testing device measures and reports the root mean square value of the breakdown voltage. After the transformer oil test is completed, the insulation oil is stirred automatically and the test sequence is performed repeatedly: typically 5 repetitions, depending on the standard.

  3. Transformer oil - Wikipedia

    en.wikipedia.org/wiki/Transformer_oil

    Transformer oil or insulating oil is an oil that is stable at high temperatures and has excellent electrical insulating properties. It is used in oil-filled wet transformers, [ 1 ] some types of high-voltage capacitors , fluorescent lamp ballasts , and some types of high-voltage switches and circuit breakers.

  4. Dissolved gas analysis - Wikipedia

    en.wikipedia.org/wiki/Dissolved_gas_analysis

    Dissolved gas analysis (DGA) is an examination of electrical transformer oil contaminants. [1] Insulating materials within electrical equipment liberate gases as they slowly break down over time. The composition and distribution of these dissolved gases are indicators of the effects of deterioration, such as pyrolysis or partial discharge , and ...

  5. Liquid dielectric - Wikipedia

    en.wikipedia.org/wiki/Liquid_dielectric

    A liquid dielectric is a dielectric material in liquid state. Its main purpose is to prevent or rapidly quench electric discharges.Dielectric liquids are used as electrical insulators in high voltage applications, e.g. transformers, capacitors, high voltage cables, and switchgear (namely high voltage switchgear).

  6. Condition monitoring of transformers - Wikipedia

    en.wikipedia.org/wiki/Condition_monitoring_of...

    PDs are initiated by defects during manufacture or higher stress dictated by design considerations. Measurements can be collected to detect these PDs and monitor the soundness of insulation. PDs manifest as sharp current pulses at transformer terminals, whose nature depends on the types of insulation, defects, measuring circuits, and detectors ...

  7. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    A dielectric withstand test may be done as a factory test on new equipment, or may be done on apparatus already in service as a routine maintenance test. [2] An insulation test set; in this pattern, a hand-cranked generator provides the high voltage and the scale is directly calibrated in megohms. Voltage withstand testing is done with a high ...

  8. Polychlorinated biphenyl - Wikipedia

    en.wikipedia.org/wiki/Polychlorinated_biphenyl

    One of the largest deliberate PCB spills in American history occurred in the summer of 1978 when 31,000 gallons (117 m^3) of PCB-contaminated oil were illegally sprayed by the Ward PCB Transformer Company in 3-foot (0.91 m) swaths along the roadsides of some 240 miles (390 km) of North Carolina highway shoulders in 14 counties and at the Fort ...

  9. Partial discharge - Wikipedia

    en.wikipedia.org/wiki/Partial_discharge

    PD can occur in a gaseous, liquid, or solid insulating medium. It often starts within gas voids, such as voids in solid epoxy insulation or bubbles in transformer oil. Protracted partial discharge can erode solid insulation and eventually lead to breakdown of insulation.