  1. Results from the WOW.Com Content Network
  2. Solar air conditioning - Wikipedia

    en.wikipedia.org/wiki/Solar_air_conditioning

    Another mini split version allows the solar panels to be plugged directly to the outside part of the unit, uses a 310v DC power bus, and offers optional 120v plug-in backup grid power to be leveraged to fill in any lack of solar power available. The advantage of these inverter DC air conditioners is the lower cost, while the disadvantage is ...

  3. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    Air-conditioner sizes are often given as "tons" of cooling, where 1 ton of cooling equals 12,000 BTU/h (3.5 kW). 1 ton of cooling equals the amount of power that needs to be applied continuously over a 24-hour period to melt 1 ton of ice. The annual cost of electric energy consumed by an air conditioner may be calculated as follows:

  4. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU/watt-hr. The higher the HSPF rating of a unit, the more energy efficient it is.

  5. Inverter compressor - Wikipedia

    en.wikipedia.org/wiki/Inverter_compressor

    Inverter compressors start slowly and avoid this startup power which is needed each time a standard on/off compressor comes on. Close control units These are used in the cooling of IT and electronic equipment used in data centres, telecommunications and in manufacturing industries. Power management, energy consumption and heat loads are major ...

  6. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    Less work is required to move heat than for conversion into heat, and because of this, heat pumps, air conditioners and refrigeration systems can have a coefficient of performance greater than one. The COP is highly dependent on operating conditions, especially absolute temperature and relative temperature between sink and system, and is often ...

  7. Load profile - Wikipedia

    en.wikipedia.org/wiki/Load_Profile

    Graphs by hour of California's total electric load, the total load less solar and wind power (known as the duck curve) and solar power output. Data is for October 22, 2016, a day when the wind power output was low and steady throughout the day. In electrical engineering, a load profile is a graph of the variation in the electrical load versus ...

  8. Sol-air temperature - Wikipedia

    en.wikipedia.org/wiki/Sol-air_temperature

    Sol-air temperature (T sol-air) is a variable used to calculate cooling load of a building and determine the total heat gain through exterior surfaces. It is an ...

  9. Heat pump and refrigeration cycle - Wikipedia

    en.wikipedia.org/wiki/Heat_pump_and...

    Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]