  2. Fire extinguisher - Wikipedia

    en.wikipedia.org/wiki/Fire_extinguisher

    An anecdotal report of a carbon dioxide fire extinguisher was published in Scientific American in 1887 which describes the case of a basement fire at a Louisville, Kentucky pharmacy which melted a lead pipe charge with CO 2 (called carbonic acid gas at the time) intended for a soda fountain which immediately extinguished the flames thus saving ...

  3. 2,2-Dichloro-1,1,1-trifluoroethane - Wikipedia

    en.wikipedia.org/wiki/2,2-Dichloro-1,1,1-trifluo...

    It is also the primary component of the Halotron I fire-extinguishing mixture. Its ozone depletion potential is ODP = 0.012, and global warming potential is GWP = 76. HCFC-123 will eventually be phased out under the current schedule of the Montreal Protocol. It was discontinued in new HVAC equipment in 2020 in developed countries but will still ...

  4. Fire control - Wikipedia

    en.wikipedia.org/wiki/Fire_control

    Understanding the cause is essential so that the correct fire extinguisher is used; if the wrong extinguisher is used, it can either make the fire worse or fail to control it. For example, using a type A, B, C fire extinguisher on a chemical fire will do the opposite of what the extinguisher is supposed to do and can cause an explosion.

  5. Odorizer - Wikipedia

    en.wikipedia.org/wiki/Odorizer

    Odorizers are used in carbon dioxide fire extinguisher systems, the odorizer assembly injects wintergreen oil into the carbon dioxide stream when the agent is discharged. Approximately 50 cc of wintergreen oil contained within a frangible glass cartridge is mounted within a protective housing attached to the discharge piping in such a manner as ...

  6. Gaseous fire suppression - Wikipedia

    en.wikipedia.org/wiki/Gaseous_fire_suppression

    Gaseous fire suppression, also called clean agent fire suppression, is the use of inert gases and chemical agents to extinguish a fire. These agents are governed by the National Fire Protection Association (NFPA) Standard for Clean Agent Fire Extinguishing Systems – NFPA 2001 in the US, with different standards and regulations elsewhere.

  7. ABC dry chemical - Wikipedia

    en.wikipedia.org/wiki/ABC_dry_chemical

    Dry chemical powder is used on all classes of fires. Dry chemical powder puts out the fire by coating the burning material with a thin layer of dust, thereby separating the fuel from the oxygen in the air. The powder also works to interrupt the chemical reaction of fire, so these extinguishers are extremely effective at putting out the fire.

  8. Fast Flow Extinguishers - Wikipedia

    en.wikipedia.org/wiki/Fast_Flow_Extinguishers

    In other words, a fast flow extinguisher expels a higher volume of agent in less time than a standard compliance flow extinguisher. As a result, fast flow extinguishers have lower UL class A&B ratings than compliance flow extinguishers (the class B numerical rating is the approximate square feet of burning fuel a novice operator could expect to ...

  9. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Classes of fire extinguisher and corresponding type of fire they extinguish. Claw tool Early striking and prying tool. Closed-circuit SCBA See SCBA. Closet hook Pike pole under 5 ft long Closet ladder See Attic ladder. CO 2 extinguisher Fire extinguisher that releases carbon dioxide gas to displace oxygen to smother and cool a fire, such as a ...