Affinity chromatography can be used in a number of applications, including nucleic acid purification, protein purification [9] from cell free extracts, and purification from blood. By using affinity chromatography, one can separate proteins that bind to a certain fragment from proteins that do not bind that specific fragment. [10]
In chemical physics and physical chemistry, chemical affinity is the electronic property by which dissimilar chemical species are capable of forming chemical compounds. [1] Chemical affinity can also refer to the tendency of an atom or compound to combine by chemical reaction with atoms or compounds of unlike composition.
Periodic counter-current chromatography (PCC) is a method for running affinity chromatography in a quasi-continuous manner. Today, the process is mainly employed for the purification of antibodies in the biopharmaceutical industry [1] as well as in research and development. When purifying antibodies, protein A is used as affinity matrix ...
Dye-ligand affinity chromatography is one of the Affinity chromatography techniques used for protein purification of a complex mixture. Like general chromatography, but using dyes to apply on a support matrix of a column as the stationary phase that will allow a range of proteins with similar active sites to bind to, refers to as pseudo-affinity.
This form of chromatography is widely used in the following applications: water purification, preconcentration of trace components, ligand-exchange chromatography, ion-exchange chromatography of proteins, high-pH anion-exchange chromatography of carbohydrates and oligosaccharides, and others.
Where classical column chromatography uses a solid phase made by a packed bed, EBA uses particles in a fluidized state, ideally expanded by a factor of 2. Expanded bed adsorption is, however, different from fluidised bed chromatography in essentially two ways: one, the EBA resin contains particles of varying size and density which results in a ...
In liquid chromatography, the mobile phase velocity is taken as the exit velocity, that is, the ratio of the flow rate in ml/second to the cross-sectional area of the ‘column-exit flow path.’ For a packed column, the cross-sectional area of the column exit flow path is usually taken as 0.6 times the cross-sectional area of the column.
The liquid flow is vaporized by nebulization and heat. The vaporized sample then enters into the radiation zone of the VUV source. Sample ions then enter into the MS interface region, frequently a capillary through the combination of a decreasing pressure gradient and electric fields.