enow.com Web Search

  1. Ad

    related to: thermometer calibration equation

Search results

  1. Results from the WOW.Com Content Network
  2. Callendar–Van Dusen equation - Wikipedia

    en.wikipedia.org/wiki/Callendar–Van_Dusen_equation

    The Callendar–Van Dusen equation is an equation that describes the relationship between resistance (R) and temperature (T) of platinum resistance thermometers (RTD). As commonly used for commercial applications of RTD thermometers, the relationship between resistance and temperature is given by the following equations.

  3. International Temperature Scale of 1990 - Wikipedia

    en.wikipedia.org/wiki/International_Temperature...

    The International Temperature Scale of 1990 (ITS-90) is an equipment calibration standard specified by the International Committee of Weights and Measures (CIPM) for making measurements on the Kelvin and Celsius temperature scales. It is an approximation of thermodynamic temperature that facilitates the comparability and compatibility of ...

  4. Thermometer - Wikipedia

    en.wikipedia.org/wiki/Thermometer

    A thermometer is a device ... Examples of these are thermometers based on the equation of ... For many modern devices calibration will be stating some value to be ...

  5. Scale of temperature - Wikipedia

    en.wikipedia.org/wiki/Scale_of_temperature

    Scale of temperature is a methodology of calibrating the physical quantity temperature in metrology.Empirical scales measure temperature in relation to convenient and stable parameters or reference points, such as the freezing and boiling point of water.

  6. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    Resistance thermometers, ... Two common calibration methods are the fixed-point method and the comparison method. ... solution of the quadratic equation yields the ...

  7. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]

  8. Steinhart–Hart equation - Wikipedia

    en.wikipedia.org/wiki/Steinhart–Hart_equation

    The equation model converts the resistance actually measured in a thermistor to its theoretical bulk temperature, with a closer approximation to actual temperature than simpler models, and valid over the entire working temperature range of the sensor.

  9. Silicon bandgap temperature sensor - Wikipedia

    en.wikipedia.org/wiki/Silicon_bandgap...

    The silicon bandgap temperature sensor is an extremely common form of ... according to the following equation: [1] ... however this requires calibration for each ...