enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Buccal object rule - Wikipedia

    en.wikipedia.org/wiki/Buccal_object_rule

    In 1909, Charles A. Clark described a radiographic procedure for localizing impacted teeth to determining their relative antero-posterior position. [1] If the two teeth (or, by extension, any two objects, such as a tooth and a foreign object) are located in front of one another relative to the x-ray beam, they will appear superimposed on one another on a dental radiograph, but it will be ...

  3. Schuller's view - Wikipedia

    en.wikipedia.org/wiki/Schuller's_view

    Schuller's view is a lateral radiographic view of skull principally used for viewing mastoid cells. [1] The central beam of X-rays passes from one side of the head and is at an angle of 25° caudad to the radiographic plate. This angulation prevents overlap of images of the two mastoid bones. The radiograph for each mastoid is taken separately.

  4. X-ray detector - Wikipedia

    en.wikipedia.org/wiki/X-ray_detector

    Fish bone pierced in the upper esophagus. Right image without contrast medium, left image during swallowing with contrast medium. To obtain an image with any type of image detector the part of the patient to be X-rayed is placed between the X-ray source and the image receptor to produce a shadow of the internal structure of that particular part of the body.

  5. Projectional radiography - Wikipedia

    en.wikipedia.org/wiki/Projectional_radiography

    Projectional radiography, also known as conventional radiography, [1] is a form of radiography and medical imaging that produces two-dimensional images by X-ray radiation. The image acquisition is generally performed by radiographers, and the images are often examined by radiologists. Both the procedure and any resultant images are often simply ...

  6. Waters' view - Wikipedia

    en.wikipedia.org/wiki/Waters'_view

    Waters' view (also known as the occipitomental view or parietoacanthial projection) is a radiographic view of the skull. It is commonly used to get a better view of the maxillary sinuses. An x-ray beam is angled at 45° to the orbitomeatal line. The rays pass from behind the head and are perpendicular to the radiographic plate.

  7. X-ray marker - Wikipedia

    en.wikipedia.org/wiki/X-ray_marker

    X-ray Markers, also known as: anatomical side markers, [1] Pb markers, lead markers, x-ray lead markers, or radiographic film identification markers, are used to mark x-ray films, both in hospitals and in industrial workplaces (such as on aeroplane parts and motors). They are used on radiographic images to determine anatomical side of body ...

  8. X-ray filter - Wikipedia

    en.wikipedia.org/wiki/X-ray_filter

    X-ray filtration may be inherent due to the X-ray tube and housing material itself or added from additional sheets of filter material. The minimum filtration used is usually 2.5 mm aluminium (Al) equivalent, although there is an increasing trend to use greater filtration.

  9. Abdominal x-ray - Wikipedia

    en.wikipedia.org/wiki/Abdominal_x-ray

    The standard abdominal X-ray protocol is usually a single anteroposterior projection in supine position. [3] Special projections include a PA prone, lateral decubitus, upright AP, and lateral cross-table (with the patient supine).