enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fire extinguisher - Wikipedia

    en.wikipedia.org/wiki/Fire_extinguisher

    An empty fire extinguisher which was not replaced for years. Most countries in the world require regular fire extinguisher maintenance by a competent person to operate safely and effectively, as part of fire safety legislation. Lack of maintenance can lead to an extinguisher not discharging when required, or rupturing when pressurized.

  3. ABC dry chemical - Wikipedia

    en.wikipedia.org/wiki/ABC_dry_chemical

    Dry chemical powder is used on all classes of fires. Dry chemical powder puts out the fire by coating the burning material with a thin layer of dust, thereby separating the fuel from the oxygen in the air. The powder also works to interrupt the chemical reaction of fire, so these extinguishers are extremely effective at putting out the fire.

  4. Air pressurized water - Wikipedia

    en.wikipedia.org/wiki/Air_pressurized_water

    A standard APW extinguisher in the United States contains 9.5 litres (2.5 US gal) of water in a stainless steel tank. The water is discharged by means of a 13 mm (1 ⁄ 2 in) hose, with a smooth-bore nozzle attached to the tip. They will initially produce a 12–15 m (40–50 ft) stream of water, with a discharge time of about 50 seconds.

  5. Glossary of firefighting equipment - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_firefighting...

    Fire extinguisher See Extinguisher above. Fire bike or firefighting motorcycle A motorcycle that is equipped to fight fires or used as support. Commonly used in Japan. Fire hose See also hose, below. Fire hydrant See hydrant. Fire pump a pump installed in a building specifically for sprinkler and standpipe water systems. Fire station alert system

  6. K-factor (fire protection) - Wikipedia

    en.wikipedia.org/wiki/K-factor_(fire_protection)

    In fire protection engineering, the K-factor formula is used to calculate the volumetric flow rate from a nozzle. Spray nozzles can for example be fire sprinklers or water mist nozzles, hose reel nozzles, water monitors and deluge fire system nozzles.

  7. Gaseous fire suppression - Wikipedia

    en.wikipedia.org/wiki/Gaseous_fire_suppression

    Gaseous fire suppression, also called clean agent fire suppression, is the use of inert gases and chemical agents to extinguish a fire. These agents are governed by the National Fire Protection Association (NFPA) Standard for Clean Agent Fire Extinguishing Systems – NFPA 2001 in the US, with different standards and regulations elsewhere.

  8. Compressed air foam system - Wikipedia

    en.wikipedia.org/wiki/Compressed_air_foam_system

    This would produce flow rates from a typical 1-3/4" inch hose of 120 US gal (450 L) per minute of foam solution and 60 cu ft (1.7 m 3) per minute of compressed air. This air to foam solution ratio produces a wet, quick draining finished foam that will quickly knockdown flame and reduce fire compartment temperature.

  9. Self-contained breathing apparatus - Wikipedia

    en.wikipedia.org/wiki/Self-contained_breathing...

    Elastomeric masks linked to backpack air tanks: self-contained breathing apparatus, worn by firefighters advancing with a firehose. There are two major application areas for SCBA: firefighting, and industrial use in confined spaces. [20] For SCBAs used in firefighting, manufacturers typically prioritize fire resistance and weight reduction over ...