enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Azobilirubin - Wikipedia

    en.wikipedia.org/wiki/Azobilirubin

    The quantity of bilirubin in patients with jaundice can be determined by the formation of azobilirubin in the presence of methanol. [2] The Van den Bergh chemical reaction which is used to measure bilirubin levels, couples bilirubin with diazotized sulfanilic acid. [2] This reaction produced azo pigments, or azobilirubin.

  3. Azotemia - Wikipedia

    en.wikipedia.org/wiki/Azotemia

    Azotemia (from azot 'nitrogen' and -emia 'blood condition'), also spelled azotaemia, is a medical condition characterized by abnormally high levels of nitrogen-containing compounds (such as urea, creatinine, various body waste compounds, and other nitrogen-rich compounds) in the blood.

  4. Van den Bergh reaction - Wikipedia

    en.wikipedia.org/wiki/Van_den_Bergh_reaction

    This test helps to identify the type of jaundice. The serum of the patient is mixed with diazo reagent. If a red colour develops immediately it is called a direct positive. It happens if conjugated bilirubin is present. In an indirect positive test, the patient's serum is first treated with alcohol and later mixed with diazo reagent.

  5. Oakland clinic gets medical device maker to disclose risk of ...

    www.aol.com/news/oakland-clinic-gets-medical...

    When Dr. Noha Aboelata learned that research stretching back decades showed that pulse oximeters routinely failed patients with darker skin, she took action.

  6. Urine test strip - Wikipedia

    en.wikipedia.org/wiki/Urine_test_strip

    An improper technique can produce false results, for example, leukocytes and erythrocytes precipitate at the bottom of the container and may not be detected if the sample is not properly mixed, and in the same way, if an excess of urine remains on the strip after it has been removed from the test sample, may cause the reagents to leak from the ...

  7. Azobenzene reductase - Wikipedia

    en.wikipedia.org/wiki/Azobenzene_reductase

    Most azoreductase isoenzymes can reduce methyl red, but are not able to reduce sulfonated azo dyes. The unique azoreductase isozyme from Bacillus sp. B29 has the ability to reduce sulfonated azo dyes however. [3]

  8. 7 blood pressure mistakes that could be throwing off your ...

    www.aol.com/news/7-blood-pressure-mistakes-could...

    Several key mistakes could throw off the accuracy of blood pressure readings for people who take them at home. The average "normal" blood pressure is 120/80, according to the American Heart ...

  9. Anti-streptolysin O - Wikipedia

    en.wikipedia.org/wiki/Anti-streptolysin_O

    A positive test usually is > 200 units/mL, [1] but normal ranges vary from laboratory to laboratory and by age. [2] The false negatives rate is 20 to 30%. [1] If a false negative is suspected, then an anti-DNase B titre should be sought. False positives can result from liver disease and tuberculosis. [1]