Fluorescent glucose biosensors are devices that measure the concentration of glucose in diabetic patients by means of sensitive protein that relays the concentration by means of fluorescence, an alternative to amperometric sension of glucose. Due to the prevalence of diabetes, it is the prime drive in the construction of fluorescent biosensors.
A common example of a commercial biosensor is the blood glucose biosensor, which uses the enzyme glucose oxidase to break blood glucose down. In doing so it first oxidizes glucose and uses two electrons to reduce the FAD (a component of the enzyme) to FADH 2. This in turn is oxidized by the electrode in a number of steps.
Enzymatic glucose biosensors use an electrode instead of O 2 to take up the electrons needed to oxidize glucose and produce an electronic current in proportion to glucose concentration. [13] This is the technology behind the disposable glucose sensor strips used by diabetics to monitor serum glucose levels. [14]
A simplified Jablonski diagram illustrating the change of energy levels.. The principle behind fluorescence is that the fluorescent moiety contains electrons which can absorb a photon and briefly enter an excited state before either dispersing the energy non-radiatively or emitting it as a photon, but with a lower energy, i.e., at a longer wavelength (wavelength and energy are inversely ...
Electrochemical aptamer-based (E-AB) biosensors is a device that takes advantage of the electrochemical and biological properties of aptamers to take real time, in vivo measurements. An electrochemical aptamer-based (E-AB) biosensor generates an electrochemical signal in response to specific target binding in vivo [ 3 ] The signal is measured ...
Bio-FETs couple a transistor device with a bio-sensitive layer that can specifically detect bio-molecules such as nucleic acids and proteins. A Bio-FET system consists of a semiconducting field-effect transistor that acts as a transducer separated by an insulator layer (e.g. SiO 2) from the biological recognition element (e.g. receptors or probe molecules) which are selective to the target ...
As soon as the glucose enters the cell, it is phosphorylated into glucose-6-phosphate in order to preserve the concentration gradient so glucose will continue to enter the cell. [7] Insulin also provides signals to several other body systems, and is the chief regulator of metabolic control in humans. [citation needed]
Method of glucose uptake differs throughout tissues depending on two factors; the metabolic needs of the tissue and availability of glucose.The two ways in which glucose uptake can take place are facilitated diffusion (a passive process) and secondary active transport (an active process which on the ion-gradient which is established through the hydrolysis of ATP, known as primary active ...