enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. High anion gap metabolic acidosis - Wikipedia

    en.wikipedia.org/wiki/High_anion_gap_metabolic...

    High anion gap metabolic acidosis is typically caused by acid produced by the body. More rarely, it may be caused by ingesting methanol or overdosing on aspirin . [ 1 ] [ 2 ] The delta ratio is a formula that can be used to assess elevated anion gap metabolic acidosis and to evaluate whether mixed acid base disorder (metabolic acidosis) is present.

  3. Anion gap - Wikipedia

    en.wikipedia.org/wiki/Anion_gap

    The calculated value of the anion gap should always be adjusted for variations in the serum albumin concentration. [15] For example, in cases of hypoalbuminemia the calculated value of the anion gap should be increased by 2.3 to 2.5 mEq/L per each 1 g/dL decrease in serum albumin concentration (refer to Sample calculations, below).

  4. Metabolic acidosis - Wikipedia

    en.wikipedia.org/wiki/Metabolic_acidosis

    In reality serum is electoneutral because of the presence of other minor cations (potassium, calcium and magnesium) and anions (albumin, sulphate and phosphate) that are not measured in the equation that calculates the anion gap. [citation needed] The normal value for the anion gap is 8–16 mmol/L (12±4).

  5. Base excess - Wikipedia

    en.wikipedia.org/wiki/Base_excess

    Base excess is defined as the amount of strong acid that must be added to each liter of fully oxygenated blood to return the pH to 7.40 at a temperature of 37°C and a pCO 2 of 40 mmHg (5.3 kPa). [2] A base deficit (i.e., a negative base excess) can be correspondingly defined by the amount of strong base that must be added.

  6. Delta ratio - Wikipedia

    en.wikipedia.org/wiki/Delta_Ratio

    The anion gap (AG) without potassium is calculated first and if a metabolic acidosis is present, results in either a high anion gap metabolic acidosis (HAGMA) or a normal anion gap acidosis (NAGMA). A low anion gap is usually an oddity of measurement, rather than a clinical concern.

  7. Urine anion gap - Wikipedia

    en.wikipedia.org/wiki/Urine_anion_gap

    The urine anion gap is an 'artificial' and calculated measure that is representative of the unmeasured ions in urine. Usually the most important unmeasured ion in urine is NH 4 + since it is the most important form of acid excretion by the kidney. [ 5 ]

  8. Hypoalbuminemia - Wikipedia

    en.wikipedia.org/wiki/Hypoalbuminemia

    Hypoalbuminemia (or hypoalbuminaemia) is a medical sign in which the level of albumin in the blood is low. [1] This can be due to decreased production in the liver, increased loss in the gastrointestinal tract or kidneys, increased use in the body, or abnormal distribution between body compartments.

  9. Osmol gap - Wikipedia

    en.wikipedia.org/wiki/Osmol_gap

    If this gap falls within an acceptable range,(<10) then it is assumed that sodium, glucose, BUN are indeed the major dissolved ions and molecules in the serum. If, however, the calculated gap is above an acceptable range, then it is an indication that there is something else dissolved in the serum that is producing an osmol gap, which can be a ...