Search results
Results from the WOW.Com Content Network
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane.. In electrocardiography, left axis deviation (LAD) is a condition wherein the mean electrical axis of ventricular contraction of the heart lies in a frontal plane direction between −30° and −90°.
Bifascicular block is a combination of right bundle branch block and either left anterior fascicular block or left posterior fascicular block. Conduction to the ventricle would therefore be via the remaining fascicle. The ECG will show typical features of RBBB plus either left or right axis deviation. [7] [8]
A mnemonic can be used for some causes of ST depression, namely DEPRESSED ST: [citation needed]. D - Drooping valve (mitral valve prolapse) E - Enlargement of the left ventricle P - Potassium loss R - Reciprocal ST depression (e.g. inferior wall MI) E - Encephalon hemorrhage S - Subendocardial infarct S - Subendocardial ischemia E - Embolism (pulmonary) D - Dilated cardiomyopathy S - Shock T ...
An ST elevation is considered significant if the vertical distance inside the ECG trace and the baseline at a point 0.04 seconds after the J-point is at least 0.1 mV (usually representing 1 mm or 1 small square) in a limb lead or 0.2 mV (2 mm or 2 small squares) in a precordial lead. [2] The baseline is either the PR interval or the TP interval ...
Electrocardiography is the process of producing an electrocardiogram (ECG or EKG [a]), a recording of the heart's electrical activity through repeated cardiac cycles. [4] It is an electrogram of the heart which is a graph of voltage versus time of the electrical activity of the heart [ 5 ] using electrodes placed on the skin.
The mean, normal SA in healthy young adult females and males is 66° and 80°, respectively, [9] and very similar magnitudes are found in the elderly population (65 years and older). [10] In ECG analysis, the SA is categorized into normal (below 105°), borderline abnormal (105–135°) and abnormal (greater than 135°). [11]
An incomplete right bundle branch block (IRBBB) is a conduction abnormality in the right bundle branch block. While a complete RBBB has a QRS duration of 120 ms or more, an incomplete RBBB has a wave duration between 100 and 120 ms.
LAFB cannot be diagnosed when a prior inferior wall myocardial infarction (IMI) is evident on the ECG. IMI can also cause extreme left-axis deviation, but will manifest with Q-waves in the inferior leads II, III, and aVF. By contrast, QRS complexes in the inferior leads should begin with r-waves in LAFB. [citation needed]