Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
(E.g. 1 mm diameter wire is ~18 AWG, 2 mm diameter wire is ~12 AWG, and 4 mm diameter wire is ~6 AWG). This quadruples the cross-sectional area and conductance. A decrease of ten gauge numbers (E.g. from 12 AWG to 2 AWG) multiplies the area and weight by approximately 10, and reduces the electrical resistance (and increases the conductance ) by ...
For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...
J. H. Neher and M. H. McGrath were two electrical engineers who wrote a paper in 1957 about how to calculate the capacity of current (ampacity) of cables. [1] The paper described two-dimensional highly symmetric simplified calculations which have formed the basis for many cable application guidelines and regulations.
The numbers of wire were in common use earlier than 1735 when the measurements were officially defined. [1] It is believed that they originally were based on the series of drawn wires, No. 1 being the original rod, and succeeding numbers corresponding with each draw, so that No. 10, for example, would have passed ten times through the draw plate.
Dynamic (electrical overhead-)line rating is a great opportunity for transmission line operators (any voltage from 15 kV to 735 kV and over). It has been studied for more than 20 years inside CIGRE and IEEE working groups.
For example, NM 14-2 cable contains three conductors (two plus one ground) at 14 gauge, a size typically used for circuits protected at 15 amperes. Circuits with larger currents (such as for electric furnaces, water heaters, air conditioners, or sub-mains to additional circuit panels) will have larger conductors.
Tri-rated cable is a high temperature, flame retardant electrical wire designed for use inside electrical equipment. Tri-rated cable meets the requirements of three different international standards: BS 6231, UL 758, and CSA 22.2. [ 1 ]