Search results
Results from the WOW.Com Content Network
Example: How many standard cubic feet are in 1 cubic foot of gas at 80 °F and gauge pressure 50 psi? (assuming that there is 13.6 psi atmospheric pressure and ignoring super compressibility) V s = 1 cu ft × [(13.6 psi + 50 psi) / 14.73 psi] × [(60 °F + 459.67 °F) / (80 °F + 459.67 °F)]
Standard cubic feet per minute (SCFM) is the molar flow rate of a gas expressed as a volumetric flow at a "standardized" temperature and pressure thus representing a fixed number of moles of gas regardless of composition and actual flow conditions.
Oil conversion factor from m³ to bbl (or stb) is 6.28981100 Gas conversion factor from standard m³ to scf is 35.314666721 Note that the m³ gas conversion factor takes into account a difference in the standard temperature base for measurement of gas volumes in metric and imperial units.
Change in volume with increasing ethanol fraction. The molar volume of a substance i is defined as its molar mass divided by its density ρ i 0: , = For an ideal mixture containing N components, the molar volume of the mixture is the weighted sum of the molar volumes of its individual components.
Using Boyle's law, the equivalent GGE at 3,600 psi (25 MPa) is 0.51 cubic feet (14 litres; 3.8 US gallons). The National Conference of Weights & Measurements (NCWM) has developed a standard unit of measurement for compressed natural gas, defined in the NIST Handbook 44 Appendix D as follows: "1 Gasoline [US] gallon equivalent (GGE) means 2.567 ...
Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.
With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...
The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .