Total harmonic distortion, or THD is a common measurement of the level of harmonic distortion present in power systems. THD can be related to either current harmonics or voltage harmonics, and it is defined as the ratio of the RMS value of all harmonics to the RMS value of the fundamental component times 100%; the DC component is neglected.
The total harmonic distortion (THD or THDi) is a measurement of the harmonic distortion present in a signal and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. Distortion factor, a closely related term, is sometimes used as a synonym.
Various properties of ripple voltage may be important depending on application: the equation of the ripple for Fourier analysis to determine the constituent harmonics; the peak (usually peak-to-peak) value of the voltage; the root mean square (RMS) value of the voltage which is a component of power transmitted; the ripple factor γ, the ratio ...
A total harmonic distortion analyzer calculates the total harmonic content of a sinewave with some distortion, expressed as total harmonic distortion (THD). A typical application is to determine the THD of an amplifier by using a very-low-distortion sinewave input and examining the output.
A distortionmeter (or more precisely distortion factor meter) is an electronic measuring instrument which displays the amount of distortion added to the original signal by an electronic circuit. Harmonic distortion
An alternative technique, total harmonic distortion measurement, cancels out the fundamental with a notch filter and measures the total remaining signal, which is total harmonic distortion plus noise; it does not give the harmonic-by-harmonic detail of an analyser. Spectrum analyzers are also used by audio engineers to assess their work.
Distortion power factor is a measure of how much the harmonic distortion of a load current decreases the average power transferred to the load. Sinusoidal voltage and non-sinusoidal current give a distortion power factor of 0.75 for this computer power supply load.
Equipment distortion can be measured using a very-low-distortion audio generator as the signal source, with appropriate equipment to measure output distortion harmonic-by-harmonic with a wave analyser, or simply total harmonic distortion. A distortion of 0.0001% can be achieved by an audio signal generator with a relatively simple circuit. [4]