enow.com Web Search

  1. Ads

    related to: installing flexible ductwork

Search results

  1. Results from the WOW.Com Content Network
  2. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    Ducts for air pollution control in a 17000 standard cubic feet per minute regenerative thermal oxidizer (RTO). A round galvanized steel duct connecting to a typical diffuser Fire-resistance rated mechanical shaft with HVAC sheet metal ducting and copper piping, as well as "HOW" (Head-Of-Wall) joint between top of concrete block wall and underside of concrete slab, firestopped with ceramic ...

  3. Microducts - Wikipedia

    en.wikipedia.org/wiki/Microducts

    A common cable installation technique for fiber cables remains cable pulling. After the duct is placed, a high-strength pull line is blown into the duct (if one has not already been pre-installed by the duct manufacturer). The pull line is attached to one end of the cable and is used to pull the cable through the duct.

  4. Cable jetting - Wikipedia

    en.wikipedia.org/wiki/Cable_Jetting

    Another capability is to install a single cable or a bundle of small ducts into an occupied duct. The most expensive activity in installing a network is the need for civil works. Thus, re-using ducts occupied with one cable, leaving some space, is a tempting and often possible and cost-effective alternative.

  5. Electrical conduit - Wikipedia

    en.wikipedia.org/wiki/Electrical_conduit

    Liquidtight flexible metal conduit (LFMC) is a metallic flexible conduit covered by a waterproof plastic coating. The interior is similar to FMC. The interior is similar to FMC. Flexible metallic tubing ( FMT ; North America ) is not the same as flexible metallic conduit (FMC) which is described in US National Electrical Code (NEC) Article 348.

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Rooftop HVAC unit with view of fresh-air intake vent Ventilation duct with outlet diffuser vent. These are installed throughout a building to move air in or out of rooms. In the middle is a damper to open and close the vent to allow more or less air to enter the space. The control circuit in a household HVAC installation.

  7. Plenum space - Wikipedia

    en.wikipedia.org/wiki/Plenum_space

    A non-plenum airspace can become a plenum airspace by accident if the ductwork is disconnected and not properly repaired and resealed. Ductwork disconnection can occur due to building damage such as earthquakes, aging, or adverse environment causing the metal to corrode and fall apart, or simply negligence on the part of building contractors ...

  1. Ads

    related to: installing flexible ductwork