enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Aluminium-conductor steel-reinforced cable - Wikipedia

    en.wikipedia.org/wiki/Aluminium-conductor_steel...

    Aluminium conductor steel-reinforced cable (ACSR) is a type of high-capacity, high-strength stranded conductor typically used in overhead power lines. The outer strands are high-purity aluminium , chosen for its good conductivity, low weight, low cost, resistance to corrosion and decent mechanical stress resistance.

  3. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    For example, the United States National Electrical Code, Table 310.15(B)(16), specifies that up to three 8 AWG copper wires having a common insulating material (THWN) in a raceway, cable, or direct burial has an ampacity of 50 A when the ambient air is 30 °C, the conductor surface temperature allowed to be 75 °C. A single insulated conductor ...

  4. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    The ampacity, or maximum allowable current, of an electric power cable depends on the allowable temperatures of the cable and any adjacent materials such as insulation or termination equipment. For insulated cables, the insulation maximum temperature is normally the limiting material property that constrains ampacity.

  5. ACCC conductor - Wikipedia

    en.wikipedia.org/wiki/ACCC_conductor

    Its light weight and softness result in roughly 30% greater conductivity than an equivalent ACSR conductor, allowing 14% more current to be carried at equal temperature. For example, 1.107 in (28.1 mm) diameter ACCC "Drake" conductor at 75 °C has an AC resistance of 106 mΩ/mile, [ 7 ] while equivalent ACSR conductor has an AC resistance of ...

  6. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one aught" wire

  7. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    Several kinds of ratings may be made available, including: real-time, indicating ampacity immediately available, without time limits should conditions remain identical; emergency ratings for a limited duration; and same-day and day-ahead forecasts. DLR computations deal with "near real-time" data, updated about every five minutes.

  8. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to be of, say, No. 10, 11, 12, etc., of the wire gauge. The circular forms of wire gauge measurement devices are the most popular, and are generally 3 + 3 ⁄ 4 inches (95 mm) in diameter, with thirty-six notches; many have the decimal ...

  9. Tri-rated cable - Wikipedia

    en.wikipedia.org/wiki/Tri-rated_cable

    Wire that is approved to BS 6231 might not carry the UL and CSA ratings, if, for example, the wire is not suitable for use at the higher 105 °C temperature that is specified for those ratings. In that case, the wire is not tri-rated. According to UL 758, the maximum operating temperature of tri-rated cable is 105 °C. British Standard BS 6231 ...