enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Aluminium-conductor steel-reinforced cable - Wikipedia

    en.wikipedia.org/wiki/Aluminium-conductor_steel...

    An ACSR conductor can in part be denoted by its stranding, for example, an ACSR conductor with 72 aluminium strands with a core of 7 steel strands will be called 72/7 ACSR conductor. [ 3 ] [ 4 ] [ 5 ] Cables generally range from #6 AWG ("6/1" – six outer aluminum conductors and one steel reinforcing conductor) to 2167 kcmil ("72/7 ...

  3. Neher–McGrath method - Wikipedia

    en.wikipedia.org/wiki/Neher–McGrath_method

    The ampacity, or maximum allowable current, of an electric power cable depends on the allowable temperatures of the cable and any adjacent materials such as insulation or termination equipment. For insulated cables, the insulation maximum temperature is normally the limiting material property that constrains ampacity.

  4. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one aught" wire

  5. Ampacity - Wikipedia

    en.wikipedia.org/wiki/Ampacity

    A single insulated conductor in free air has 70 A rating. Ampacity rating is normally for continuous current, and short periods of overcurrent occur without harm in most cabling systems. Electrical code rules will give ratings for wiring where short-term loads are present, for example, in a hoisting motor.

  6. ACCC conductor - Wikipedia

    en.wikipedia.org/wiki/ACCC_conductor

    Its light weight and softness result in roughly 30% greater conductivity than an equivalent ACSR conductor, allowing 14% more current to be carried at equal temperature. For example, 1.107 in (28.1 mm) diameter ACCC "Drake" conductor at 75 °C has an AC resistance of 106 mΩ/mile, [ 7 ] while equivalent ACSR conductor has an AC resistance of ...

  7. Dynamic line rating for electric utilities - Wikipedia

    en.wikipedia.org/wiki/Dynamic_line_rating_for...

    Several kinds of ratings may be made available, including: real-time, indicating ampacity immediately available, without time limits should conditions remain identical; emergency ratings for a limited duration; and same-day and day-ahead forecasts. DLR computations deal with "near real-time" data, updated about every five minutes.

  8. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to be of, say, No. 10, 11, 12, etc., of the wire gauge. The circular forms of wire gauge measurement devices are the most popular, and are generally 3 + 3 ⁄ 4 inches (95 mm) in diameter, with thirty-six notches; many have the decimal ...

  9. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    In both those instances the white wire should be identified as being hot, usually with black tape inside junction boxes. The neutral wire is identified by gray or white insulated wire, perhaps using stripes or markings. With lamp cord wire the ribbed wire is the neutral, and the smooth wire is the hot. NEC 2008 400.22(f) allows surface marking ...