enow.com Web Search

  1. Ads

    related to: 1 inch actuated ball valve for chiller system diagram model

Search results

  1. Results from the WOW.Com Content Network
  2. Flow control valve - Wikipedia

    en.wikipedia.org/wiki/Flow_control_valve

    Pneumatically-actuated globe valves and diaphragm valves are widely used for control purposes in many industries, although quarter-turn types such as (modified) ball and butterfly valves are also used. Control valves can also work with hydraulic actuators (also known as hydraulic pilots). These types of valves are also known as automatic ...

  3. Automatic balancing valve - Wikipedia

    en.wikipedia.org/wiki/Automatic_balancing_valve

    Minimum 1.5 ft/s (0.46 m/s) (based on a Reynolds number of 7500) Minimum flow is typically 50% or less of the design flow. [1] Chiller manufacturers typically limit the tube velocities in the range from 5.0 to 10.0 feet per second (1.5 to 3.0 m/s). [2]

  4. Ball valve - Wikipedia

    en.wikipedia.org/wiki/Ball_valve

    A ball valve is a flow control device which uses a hollow, perforated, and pivoting ball to control fluid flowing through it. It is open when the hole through the middle of the ball is in line with the flow inlet, and closed when it is pivoted 90 degrees by the valve handle, blocking the flow. [1]

  5. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    During the design stage, the diagram also provides the basis for the development of system control schemes, allowing for further safety and operational investigations, such as a Hazard and operability study (HAZOP). To do this, it is critical to demonstrate the physical sequence of equipment and systems, as well as how these systems connect.

  6. Control valve - Wikipedia

    en.wikipedia.org/wiki/Control_valve

    A control valve is a valve used to control fluid flow by varying the size of the flow passage as directed by a signal from a controller. [1] This enables the direct control of flow rate and the consequential control of process quantities such as pressure, temperature, and liquid level.

  7. Solenoid valve - Wikipedia

    en.wikipedia.org/wiki/Solenoid_valve

    For example, a popular 3 ⁄ 4-inch 150 psi sprinkler valve, intended for 24 VAC (50–60 Hz) residential systems, has a momentary inrush of 7.2 VA, and a holding power requirement of 4.6 VA. [5] Comparatively, an industrial 1 ⁄ 2 -inch 10,000 psi valve, intended for 12, 24, or 120 VAC systems in high-pressure fluid and cryogenic applications ...

  1. Ads

    related to: 1 inch actuated ball valve for chiller system diagram model