enow.com Web Search

  1. Ads

    related to: rtd thermocouple thermistor difference definition

Search results

  1. Results from the WOW.Com Content Network
  2. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    A standard RTD sheath is 3.175 to 6.35 mm (0.1250 to 0.2500 in) in diameter; sheath diameters for thermocouples can be less than 1.6 mm (0.063 in). Accuracy and stability requirements If a tolerance of 2 °C is acceptable and the highest level of repeatability is not required, a thermocouple will serve.

  3. Thermopile - Wikipedia

    en.wikipedia.org/wiki/Thermopile

    Thermocouples can be connected in series as thermocouple pairs with a junction located on either side of a thermal resistance layer. The output from the thermocouple pair will be a voltage directly proportional to the temperature difference across the thermal resistance layer and also to the heat flux through the thermal resistance layer.

  4. Thermistor - Wikipedia

    en.wikipedia.org/wiki/Thermistor

    A thermistor is a semiconductor type of resistor whose resistance is strongly dependent on temperature, more so than in standard resistors. The word thermistor is a portmanteau of thermal and resistor. Thermistors are categorized based on their conduction models.

  5. Thermocouple - Wikipedia

    en.wikipedia.org/wiki/Thermocouple

    A thermocouple, also known as a "thermoelectrical thermometer", is an electrical device consisting of two dissimilar electrical conductors forming an electrical junction.A thermocouple produces a temperature-dependent voltage as a result of the Seebeck effect, and this voltage can be interpreted to measure temperature.

  6. Temperature measurement - Wikipedia

    en.wikipedia.org/wiki/Temperature_measurement

    Resistance temperature detector (RTD) Pyrometer; Langmuir probes (for electron temperature of a plasma) Infrared thermometer; Other thermometers; One must be careful when measuring temperature to ensure that the measuring instrument (thermometer, thermocouple, etc.) is really the same temperature as the material that is being measured.

  7. Test probe - Wikipedia

    en.wikipedia.org/wiki/Test_probe

    A thermocouple probe. Temperature probes are used to make contact measurements of surface temperatures. They employ a temperature sensor such as a thermistor, thermocouple, or RTD, to produce a voltage that varies with temperature. In the case of thermistor and RTD probes, the sensor must be electrically stimulated to produce a voltage, whereas ...

  8. Signal conditioning - Wikipedia

    en.wikipedia.org/wiki/Signal_conditioning

    Sensor inputs can be accelerometer, thermocouple, thermistor, resistance thermometer, strain gauge or bridge, and LVDT or RVDT. Specialized inputs include encoder, counter or tachometer, timer or clock, relay or switch, and other specialized inputs. Outputs for signal conditioning equipment can be voltage, current, frequency, timer or counter ...

  9. Electronic component - Wikipedia

    en.wikipedia.org/wiki/Electronic_component

    Thermocouple, thermopile – Wires that generate a voltage proportional to delta temperature; Thermistor – Resistor whose resistance changes with temperature, up PTC or down NTC; Resistance Temperature Detector (RTD) – Wire whose resistance changes with temperature; Bolometer – Device for measuring the power of incident electromagnetic ...