enow.com Web Search

  1. Ads

    related to: coagulation studies normal values of glucose in blood

Search results

  1. Results from the WOW.Com Content Network
  2. Reference ranges for blood tests - Wikipedia

    en.wikipedia.org/wiki/Reference_ranges_for_blood...

    Reference ranges (reference intervals) for blood tests are sets of values used by a health professional to interpret a set of medical test results from blood samples. Reference ranges for blood tests are studied within the field of clinical chemistry (also known as "clinical biochemistry", "chemical pathology" or "pure blood chemistry"), the ...

  3. Prothrombin time - Wikipedia

    en.wikipedia.org/wiki/Prothrombin_time

    A similar form of testing is used by people with diabetes for monitoring blood sugar levels, which is easily taught and routinely practiced. [citation needed] Local policy determines whether the patient or a coagulation specialist (pharmacist, nurse, general practitioner or hospital doctor) interprets the result and determines the dose of ...

  4. Blood sugar level - Wikipedia

    en.wikipedia.org/wiki/Blood_sugar_level

    Blood sugar levels for those without diabetes and who are not fasting should be below 6.9 mmol/L (125 mg/dL). [12] Despite widely variable intervals between meals or the occasional consumption of meals with a substantial carbohydrate load, human blood glucose levels tend to remain within the normal range. However, shortly after eating, the ...

  5. Mixing study - Wikipedia

    en.wikipedia.org/wiki/Mixing_study

    Fresh normal plasma has all the blood coagulation factors with normal levels. If the problem is a simple factor deficiency, mixing the patient plasma 1:1 with plasma that contains 100% of the normal factor level results in a level ≥50% in the mixture (say the patient has an activity of 0%; the average of 100% + 0% = 50%). [3]

  6. Clotting time - Wikipedia

    en.wikipedia.org/wiki/Clotting_time

    Clotting time is a general term for the time required for a sample of blood to form a clot, or, in medical terms, coagulate.The term "clotting time" is often used when referring to tests such as the prothrombin time (PT), activated partial thromboplastin time (aPTT or PTT), activated clotting time (ACT), thrombin time (TT), or Reptilase time.

  7. Glucose test - Wikipedia

    en.wikipedia.org/wiki/Glucose_test

    A level below 5.6 mmol/L (100 mg/dL) 10–16 hours without eating is normal. 5.6–6 mmol/L (100–109 mg/dL) may indicate prediabetes and oral glucose tolerance test (OGTT) should be offered to high-risk individuals (old people, those with high blood pressure etc.). 6.1–6.9 mmol/L (110–125 mg/dL) means OGTT should be offered even if other ...

  8. Coagulation testing - Wikipedia

    en.wikipedia.org/wiki/Coagulation_testing

    Blood clotting tests are the tests used for diagnostics of the hemostasis system. Coagulometer is the medical laboratory analyzer used for testing of the hemostasis system. Modern coagulometers realize different methods of activation and observation of development of blood clots in blood or in blood plasma. [citation needed]

  9. Random glucose test - Wikipedia

    en.wikipedia.org/wiki/Random_glucose_test

    The reference values for a "normal" random glucose test in an average adult are 80–140mg/dl (4.4–7.8 mmol/l), between 140 and 200mg/dl (7.8–11.1 mmol/l) is considered pre-diabetes [citation needed], and ≥ 200 mg/dl is considered diabetes according to ADA guidelines [1] (you should visit your doctor or a clinic for additional tests however as a random glucose of > 160mg/dl does not ...

  1. Ads

    related to: coagulation studies normal values of glucose in blood