enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Resistance thermometer - Wikipedia

    en.wikipedia.org/wiki/Resistance_thermometer

    UPRTs have a wide temperature range (−200 °C to 1000 °C) and are approximately accurate to ±0.001 °C over the temperature range. UPRTs are only appropriate for laboratory use. Another classification of laboratory PRTs is Standard Platinum Resistance Thermometers (Standard SPRTs). They are constructed like the UPRT, but the materials are ...

  3. Intermittent fault - Wikipedia

    en.wikipedia.org/wiki/Intermittent_fault

    A simple example of an effectively random cause in a physical system is a borderline electrical connection in the wiring or a component of a circuit, where (cause 1, the cause that must be identified and rectified) two conductors may touch subject to (cause 2, which need not be identified) a minor change in temperature, vibration, orientation ...

  4. Silicon bandgap temperature sensor - Wikipedia

    en.wikipedia.org/wiki/Silicon_bandgap...

    A circuit that forces I C1 and I C2 to have a fixed N:1 ratio, [2] gives the relationship: = ⁡ An electronic circuit, such as the Brokaw bandgap reference, that measures ΔV BE can therefore be used to calculate the temperature of the diode. The result remains valid up to about 200 °C to 250 °C, when leakage currents become large enough to ...

  5. Thermistor - Wikipedia

    en.wikipedia.org/wiki/Thermistor

    An NTC is commonly used as a temperature sensor, or in series with a circuit as an inrush current limiter. With PTC thermistors, resistance increases as temperature rises; usually because of increased thermal lattice agitations, particularly those of impurities and imperfections. PTC thermistors are commonly installed in series with a circuit ...

  6. Overheating (electricity) - Wikipedia

    en.wikipedia.org/wiki/Overheating_(electricity)

    Circuit-breakers can be placed at portions of a circuit in series to the path of current it will affect. If more current than expected goes through the circuit-breaker, the circuit breaker "opens" the circuit and stops all current. A fuse is a common type of circuit breaker that involves direct effect of Joule-overheating.

  7. IR35 - Wikipedia

    en.wikipedia.org/wiki/IR35

    IR35 is the United Kingdom's anti-avoidance tax legislation, the intermediaries legislation contained in Chapter 8 of Income Tax (Earnings and Pensions) Act 2003. The legislation is designed to tax 'disguised' employment at a rate similar to employment.

  8. Thermal conductance and resistance - Wikipedia

    en.wikipedia.org/wiki/Thermal_conductance_and...

    The SI unit of absolute thermal resistance is kelvins per watt (K/W) or the equivalent degrees Celsius per watt (°C/W) – the two are the same since the intervals are equal: ΔT = 1 K = 1 °C. The thermal resistance of materials is of great interest to electronic engineers because most electrical components generate heat and need to be cooled.

  9. Infrared thermometer - Wikipedia

    en.wikipedia.org/wiki/Infrared_thermometer

    The most common infrared thermometer is the spot infrared pyrometer or infrared pyrometer, which measures the temperature at a spot on a surface (actually a relatively small area determined by the D:S ratio). These usually project a visible red dot onto the center of the area being measured that identifies the spot being measured, but plays no ...