enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Nyquist stability criterion - Wikipedia

    en.wikipedia.org/wiki/Nyquist_stability_criterion

    The Nyquist plot for () = + + with s = jω.. In control theory and stability theory, the Nyquist stability criterion or Strecker–Nyquist stability criterion, independently discovered by the German electrical engineer Felix Strecker [] at Siemens in 1930 [1] [2] [3] and the Swedish-American electrical engineer Harry Nyquist at Bell Telephone Laboratories in 1932, [4] is a graphical technique ...

  3. Hall circles - Wikipedia

    en.wikipedia.org/wiki/Hall_circles

    Nichols plot of the transfer function 1/s(1+s)(1+2s) along with the modified M and N circles. To use the Hall circles, a plot of M and N circles is done over the Nyquist plot of the open-loop transfer function. The points of the intersection between these graphics give the corresponding value of the closed-loop transfer function.

  4. Transfer function - Wikipedia

    en.wikipedia.org/wiki/Transfer_function

    In engineering, a transfer function (also known as system function [1] or network function) of a system, sub-system, or component is a mathematical function that models the system's output for each possible input. [2] [3] [4] It is widely used in electronic engineering tools like circuit simulators and control systems.

  5. Optical transfer function - Wikipedia

    en.wikipedia.org/wiki/Optical_transfer_function

    The relative contrast is given by the absolute value of the optical transfer function, a function commonly referred to as the modulation transfer function (MTF). Its values indicate how much of the object's contrast is captured in the image as a function of spatial frequency.

  6. H-infinity methods in control theory - Wikipedia

    en.wikipedia.org/wiki/H-infinity_methods_in...

    The achievable H ∞ norm of the closed loop system is mainly given through the matrix D 11 (when the system P is given in the form (A, B 1, B 2, C 1, C 2, D 11, D 12, D 22, D 21)). There are several ways to come to an H ∞ controller: A Youla-Kucera parametrization of the closed loop often leads to very high-order controller.

  7. Chebyshev filter - Wikipedia

    en.wikipedia.org/wiki/Chebyshev_filter

    All 16 poles are shown. Each zero has multiplicity of two, and 12 zeroes are shown and four are located outside the picture, two on the positive ω axis, and two on the negative. The poles of the transfer function are poles on the left half plane and the zeroes of the transfer function are the zeroes, but with multiplicity 1.

  8. Ziegler–Nichols method - Wikipedia

    en.wikipedia.org/wiki/Ziegler–Nichols_method

    The Ziegler–Nichols tuning method is a heuristic method of tuning a PID controller.It was developed by John G. Ziegler and Nathaniel B. Nichols.It is performed by setting the I (integral) and D (derivative) gains to zero.

  9. Nichols plot - Wikipedia

    en.wikipedia.org/wiki/Nichols_plot

    A Nichols plot. The Nichols plot is a plot used in signal processing and control design, named after American engineer Nathaniel B. Nichols. [1] [2] [3] It plots the phase response versus the response magnitude of a transfer function for any given frequency, and as such is useful in characterizing a system's frequency response.