  2. Voltage control and reactive power management - Wikipedia

    en.wikipedia.org/wiki/Voltage_control_and...

    injection of reactive power into transmission lines causes losses that waste power, forcing an increase in power supplied by the prime mover. Use of specialized voltage control devices in the grid also improves the power system stability by reducing the fluctuations of the rotor angle of a synchronous generator (that are caused by generators ...

  3. AC power - Wikipedia

    en.wikipedia.org/wiki/AC_power

    Reactive power does not do any work, so it is represented as the imaginary axis of the vector diagram. Active power does do work, so it is the real axis. The unit for power is the watt (symbol: W). Apparent power is often expressed in volt-amperes (VA) since it is the product of RMS voltage and RMS current. The unit for reactive power is var ...

  4. Flexible AC transmission system - Wikipedia

    en.wikipedia.org/wiki/Flexible_AC_transmission...

    Heavily loaded lines consumed reactive power due to the line's inductance, and as transmission voltage increased throughout the 20th century, the higher voltage supplied capacitive reactive power. As operating a transmission line only at it surge impedance loading (SIL) was not feasible, [2] other means to manage the reactive power was needed.

  5. HVDC converter station - Wikipedia

    en.wikipedia.org/wiki/HVDC_converter_station

    When line commutated converters are used, the converter station will require between 40% and 60% of its power rating as reactive power. This can be provided by banks of switched capacitors or by synchronous condensers, or if a suitable power generating station is located close to the static inverter plant, the generators in the power station ...

  6. Static VAR compensator - Wikipedia

    en.wikipedia.org/wiki/Static_VAR_compensator

    In Electrical Engineering, a static VAR compensator (SVC) is a set of electrical devices for providing fast-acting reactive power on high-voltage electricity transmission networks. [1] [2] SVCs are part of the flexible AC transmission system [3] [4] device family, regulating voltage, power factor, harmonics and stabilizing the system. A static ...

  7. Electric power system - Wikipedia

    en.wikipedia.org/wiki/Electric_power_system

    The reactive power like the real power must balance (that is the reactive power produced on a system must equal the reactive power consumed) and can be supplied from the generators, however it is often more economical to supply such power from capacitors (see "Capacitors and reactors" below for more details).

  8. Capability curve - Wikipedia

    en.wikipedia.org/wiki/Capability_curve

    In practice, the prime mover (a power source that drives the generator) is designed for less active power than the generator is capable of (due to the fact that in real life generator always has to deliver some reactive power [2]), so a prime mover limit (a vertical dashed line on the illustration) changes the constraints somewhat (in the ...

  9. Characteristic impedance - Wikipedia

    en.wikipedia.org/wiki/Characteristic_impedance

    In electric power transmission, the characteristic impedance of a transmission line is expressed in terms of the surge impedance loading (SIL), or natural loading, being the power loading at which reactive power is neither produced nor absorbed: = in which is the RMS line-to-line voltage in volts.