Single-phase motors may have taps to allow their use on either 208-volt or 240-volt supply. A single-phase load may be powered directly from a three-phase distribution transformer in two ways: by connection between one phase and neutral or by connection between two phases. These two give different voltages from a given supply.
Induction motors are most commonly run on single-phase or three-phase power, but two-phase motors exist; in theory, induction motors can have any number of phases. Many single-phase motors having two windings can be viewed as two-phase motors, since a capacitor is used to generate a second power phase 90° from the single-phase supply and feeds ...
Wire crossover symbols for circuit diagrams. The CAD symbol for insulated crossing wires is the same as the older, non-CAD symbol for non-insulated crossing wires. To avoid confusion, the wire "jump" (semi-circle) symbol for insulated wires in non-CAD schematics is recommended (as opposed to using the CAD-style symbol for no connection), so as to avoid confusion with the original, older style ...
The shaded-pole motor is the original type of AC single-phase electric motor, dating back to at least as early as 1890. [1] A shaded-pole motor is a motor, in which the auxiliary winding is composed of a copper ring or bar surrounding a portion of each pole to produce a weakly rotating magnetic field . [ 2 ]
The circle diagram can be drawn for alternators, synchronous motors, transformers, induction motors. The Heyland diagram is an approximate representation of a circle diagram applied to induction motors, which assumes that stator input voltage, rotor resistance and rotor reactance are constant and stator resistance and core loss are zero.
A DC armature of a miniature motor (or generator) An example of a triple-T armature A partially-constructed DC armature, showing the (incomplete) windings In electrical engineering, the armature is the winding (or set of windings) of an electric machine which carries alternating current. [1]
A variation of the centrifugal switch used a changeover contact to ensure that the auxiliary windings remain in the circuit through a running capacitor. These motors are called two-value or capacitor start capacitor run motors. Centrifugal switches are found in many clothes dryers, supplying power to the motor in parallel with the start switch ...
A typical one-line diagram with annotated power flows. Red boxes represent circuit breakers, grey lines represent three-phase bus and interconnecting conductors, the orange circle represents an electric generator, the green spiral is an inductor, and the three overlapping blue circles represent a double-wound transformer with a tertiary winding.