enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Duct leakage testing - Wikipedia

    en.wikipedia.org/wiki/Duct_leakage_testing

    The blower door manual will include a correction table to determine a correction factor based on the pressure in the duct work. To calculate the duct leakage to outside, subtract the leakage with the registers sealed from the total building leakage and multiply by the correction factor. [1]

  3. Leak detection - Wikipedia

    en.wikipedia.org/wiki/Leak_detection

    A leak appearing within an analytic region (a rule added to the camera) is immediately analyzed for its attributes, including thermal temperature, size, and behaviour (e.g. spraying, pooling, spilling). When a leak is determined to be valid based on set parameters, an alarm notification with leak video is generated and sent to a monitoring station.

  4. Tracer-gas leak testing - Wikipedia

    en.wikipedia.org/wiki/Tracer-gas_leak_testing

    On planes, tracer-gas leak testing is used to quickly and safely locate fuel leaks, [3] as well as to check oxygen distribution devices and cabin pressurization systems. Refrigeration and air conditioning must have the lowest possible rate of loss of refrigerant gases (contributing to ozone depletion).

  5. Joule–Thomson effect - Wikipedia

    en.wikipedia.org/wiki/Joule–Thomson_effect

    The gas-cooling throttling process is commonly exploited in refrigeration processes such as liquefiers in air separation industrial process. [7] [8] In hydraulics, the warming effect from Joule–Thomson throttling can be used to find internally leaking valves as these will produce heat which can be detected by thermocouple or thermal-imaging ...

  6. Accidental release source terms - Wikipedia

    en.wikipedia.org/wiki/Accidental_release_source...

    The above equations calculate the initial instantaneous mass flow rate for the pressure and temperature existing in the source vessel when a release first occurs. The initial instantaneous flow rate from a leak in a pressurized gas system or vessel is much higher than the average flow rate during the overall release period because the pressure ...

  7. Flash evaporation - Wikipedia

    en.wikipedia.org/wiki/Flash_evaporation

    This is often referred to as "auto-refrigeration" and is the basis of most conventional vapor compression refrigeration systems. If the saturated liquid is a multi-component liquid (for example, a mixture of propane, isobutane and normal butane), the flashed vapor is richer in the more volatile components than is the remaining liquid.

  8. Blower door - Wikipedia

    en.wikipedia.org/wiki/Blower_door

    Fan airflow is determined using C Fan and n Fan values that are provided by the blower door manufacturer, and they are used to calculate Q Fan. The multi-point blower door test procedure results in a series of known values of Q n, Fan and ∆P n, Building. Typical ∆P n, Building values are ±5, 10, 20, 30, 40 and 50 pascal.

  9. Section 608 - Wikipedia

    en.wikipedia.org/wiki/Section_608

    If the leak is not to be repaired, there must be a plan to retire or retrofit the appliance within 30 days, to be completed within one year. [10] If more than a year is required, a report must be submitted, which must include: Estimated date(s) of completion; The type of process; The leak rate; Method to determine the leak; Full unit charge ...