enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Centrifugal pump selection and characteristics - Wikipedia

    en.wikipedia.org/wiki/Centrifugal_pump_selection...

    Pump Characteristic curve; the head produced reduces with the discharge of the pump. Pump curves are quite useful in the pump selection, testing, operation and maintenance. Pump performance curve is a graph of differential head against the operating flow rate. They specify performance and efficiency characteristics.

  3. Thermodynamic pump testing - Wikipedia

    en.wikipedia.org/wiki/Thermodynamic_pump_testing

    The conventional pump testing method is a method which relies on flow measurements rather than temperature measurements to obtain the performance curves of pumps. Hence, the thermodynamic method differs from the conventional pump testing method largely in what is measured, and how those values are calculated. [6]

  4. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    The metric equivalent flow factor (K v) is calculated using metric units: =, where [3]. K v is the flow factor (expressed in m 3 /h), Q is the flowrate (expressed in m 3 /h), SG is the specific gravity of the fluid (for water = 1),

  5. Affinity laws - Wikipedia

    en.wikipedia.org/wiki/Affinity_laws

    The affinity laws (also known as the "Fan Laws" or "Pump Laws") for pumps/fans are used in hydraulics, hydronics and/or HVAC to express the relationship between variables involved in pump or fan performance (such as head, volumetric flow rate, shaft speed) and power. They apply to pumps, fans, and hydraulic turbines. In these rotary implements ...

  6. Net positive suction head - Wikipedia

    en.wikipedia.org/wiki/Net_positive_suction_head

    If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.

  7. Total dynamic head - Wikipedia

    en.wikipedia.org/wiki/Total_dynamic_head

    In fluid dynamics, total dynamic head (TDH) is the work to be done by a pump, per unit weight, per unit volume of fluid.TDH is the total amount of system pressure, measured in feet, where water can flow through a system before gravity takes over, and is essential for pump specification.

  8. Hydraulic head - Wikipedia

    en.wikipedia.org/wiki/Hydraulic_head

    The static head of a pump is the maximum height (pressure) it can deliver. The capability of the pump at a certain RPM can be read from its Q-H curve (flow vs. height). Head is useful in specifying centrifugal pumps because their pumping characteristics tend to be independent of the fluid's density. There are generally four types of head:

  9. Circulator pump - Wikipedia

    en.wikipedia.org/wiki/Circulator_pump

    These are called the pump curves. They are determined by studies, whose methodology is standardized. These curves are specified when water is pumped with a density of 1000 kg/m3 and kinematic viscosity of 1 mm2/s. When the circulating pump is used for liquids of different density and viscosity, the pump curves have to be recalculated.