If compression is performed by a mechanically driven compressor or blower, this evaporation process is usually referred to as MVR (mechanical vapor recompression). In case of compression performed by high pressure motive steam ejectors, the process is usually called thermocompression, steam compression or ejectocompression. [citation needed]
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
A vapor compression chiller typically uses one of four types of compressor: Reciprocating compression, scroll compression, screw-driven compression, and centrifugal compression are all mechanical machines that can be powered by electric motors, steam, or gas turbines. Using electric motors in a semi-hermetic or hermetic configuration is the ...
With the vapor mechanical compression technologies, cooling can be used during these periods so that the performance and the power output of the turbine may be less affected by ambient conditions Another benefit is the lower cost per extra inlet-cooling kilowatt compared to newly installed gas turbine kilowatt [ citation needed ] .
Mechanical vapor recompression (MVR) is an energy recovery process which can be used to recycle waste heat to improve efficiency. [ 1 ] [ 2 ] Typically, the compressed vapor is fed back to help heat the mother liquor in order to produce more vapor or steam.
These compressors can inject refrigerant from an internal heat exchanger, rather than the main evaporator, into the final stage of the compression process. [citation needed] In this setup, the refrigerant liquid is subcooled at high pressure in the heat exchanger, a process known as mechanical subcooling. Booster systems are another approach ...
Principal view of the pumping action of a twin-screw pump with a six-lobe female screw and a five-lobe male screw. A compressor (as opposed to a pump) would be shaped the same way, except that the shape of the lobes would change along the length of the screw, so that the volume of the trapped pockets would get squeezed smaller as they get closer to the exhaust port.
This is often referred to as "auto-refrigeration" and is the basis of most conventional vapor compression refrigeration systems. If the saturated liquid is a multi-component liquid (for example, a mixture of propane, isobutane and normal butane), the flashed vapor is richer in the more volatile components than is the remaining liquid.