enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Standard_RAID_levels

    RAID 0 (also known as a stripe set or striped volume) splits ("stripes") data evenly across two or more disks, without parity information, redundancy, or fault tolerance. Since RAID 0 provides no fault tolerance or redundancy, the failure of one drive will cause the entire array to fail, due to data being striped across all disks.

  3. Nested RAID levels - Wikipedia

    en.wikipedia.org/wiki/Nested_RAID_levels

    RAID 01, also called RAID 0+1, is a RAID level using a mirror of stripes, achieving both replication and sharing of data between disks. [3] The usable capacity of a RAID 01 array is the same as in a RAID 1 array made of the same drives, in which one half of the drives is used to mirror the other half.

  4. RAID - Wikipedia

    en.wikipedia.org/wiki/RAID

    RAID (/ r eɪ d /; redundant array of inexpensive disks or redundant array of independent disks) [1] [2] is a data storage virtualization technology that combines multiple physical data storage components into one or more logical units for the purposes of data redundancy, performance improvement, or both.

  5. Fault tolerance - Wikipedia

    en.wikipedia.org/wiki/Fault_tolerance

    There is a difference between fault tolerance and systems that rarely have problems. For instance, the Western Electric crossbar systems had failure rates of two hours per forty years, and therefore were highly fault resistant. But when a fault did occur they still stopped operating completely, and therefore were not fault tolerant.

  6. Non-standard RAID levels - Wikipedia

    en.wikipedia.org/wiki/Non-standard_RAID_levels

    RAID 5E, RAID 5EE, and RAID 6E (with the added E standing for Enhanced) generally refer to variants of RAID 5 or 6 with an integrated hot-spare drive, where the spare drive is an active part of the block rotation scheme. This spreads I/O across all drives, including the spare, thus reducing the load on each drive, increasing performance.

  7. Disk array controller - Wikipedia

    en.wikipedia.org/wiki/Disk_array_controller

    Those RAID systems made their way to the consumer market, for users wanting the fault-tolerance of RAID without investing in expensive SCSI drives. Fast consumer drives make it possible to build RAID systems at lower cost than with SCSI, but most ATA RAID controllers lack a dedicated buffer or high-performance XOR hardware for parity calculation.

  8. Data redundancy - Wikipedia

    en.wikipedia.org/wiki/Data_redundancy

    In computer main memory, auxiliary storage and computer buses, data redundancy is the existence of data that is additional to the actual data and permits correction of errors in stored or transmitted data.

  9. Non-RAID drive architectures - Wikipedia

    en.wikipedia.org/wiki/Non-RAID_drive_architectures

    A flawed RAID 5/6 also exists, but can result in data loss.) [10] For RAID 1, the devices must have complementary sizes. For example, a filesystem spanning two 500 GB devices and one 1 TB device could provide RAID1 for all data, while a filesystem spanning a 1 TB device and a single 500 GB device could only provide RAID1 for 500 GB of data.