Sprinkler fitting is a skilled trade that consists of assembling, installing, testing, repairing, inspecting, and certifying automatic fire suppression systems and their associated piping in commercial, industrial and residential buildings.
Conserve Water During Testing – NFPA-25 requires that the fire pump controller is operated for 10 minutes each week. This ends up using a substantial amount of water in buildings that have static pressures greater than 175 PSI and relies on a system relief valve to control the pressure: (50–100% of the rating of the pump) × (10minutes) × ...
The hydraulic calculation procedure is defined in the applicable reference model codes such as that published by the US-based National Fire Protection Association (NFPA), [2] or the EN 12845 standard, Fixed firefighting system – Automatic sprinkler systems – Design, installation and maintenance. [3]
The committee's initial report evolved into NFPA 13, Standard for the Installation of Sprinkler Systems, the most widely used fire sprinkler standard. [ 6 ] Around 1904, the NFPA began to expand its membership from affiliates of fire insurance companies to many other organizations and individuals, and also expanded its mission beyond ...
A fire sprinkler system is an active fire protection method, consisting of a water supply system providing adequate pressure and flowrate to a water distribution piping system, to which fire sprinklers are connected. Although initially used only in factories and large commercial buildings, systems for homes and small buildings are now available ...
A jockey pump, also known as a pressure-maintenance pump, is a small pump connected to a fire suppression system near the fire pump and is intended to maintain pressure in a fire protection piping system. These pumps recover pressures lost from gradual, slow pressure declines in a system due to temperature changes, trapped air escapement, or ...
The systems are required to operate within the limits of Class 2 remote control and signal circuits as defined by the National Electrical Code, NFPA 70. [ 15 ] The fifth edition of this standard, issued on January 31, 2018, was notable for expanding the media to include website information.
A fire test is a means of determining whether fire protection products meet minimum performance criteria as set out in a building code or other applicable legislation. Successful tests in laboratories holding national accreditation for testing and certification result in the issuance of a certification listing .