enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Fusion beat - Wikipedia

    en.wikipedia.org/wiki/Fusion_beat

    This contrasts with the pseudofusion beat wherein the pacemaker impulse does not affect the complex of the natural beat of the heart. Pseudofusion beats are normal. Rare or isolated fusion beats caused by pacemakers are normal as well, but if they occur too frequently may reduce cardiac output and so can require adjustment of the pacemaker. [3]

  3. Pre-excitation syndrome - Wikipedia

    en.wikipedia.org/wiki/Pre-excitation_syndrome

    Pre-excitation syndrome is a heart condition in which part of the cardiac ventricles are activated too early. [1] Pre-excitation is caused by an abnormal electrical connection or accessory pathway between or within the cardiac chambers.

  4. Electrophysiology study - Wikipedia

    en.wikipedia.org/wiki/Electrophysiology_study

    Doctors conduct an electrophysiology study in the hospital's cardiac catheterization laboratory. The next step is pacing the heart, this means he/she will speed up or slow down the heart by placing the electrode at certain points along the conductive pathways of the heart and control the depolarization rate of the heart.

  5. Wandering atrial pacemaker - Wikipedia

    en.wikipedia.org/wiki/Wandering_atrial_pacemaker

    Wandering atrial pacemaker may be seen in young, healthy individuals as well as in the elderly and those with lung disease. [2] The cause of wandering atrial pacemaker is unclear. Increased tone from the vagus nerve may factor into the rhythm appearing in young, healthy individuals who exercise. The vagus nerve is a part of the parasympathetic ...

  6. Junctional rhythm - Wikipedia

    en.wikipedia.org/wiki/Junctional_rhythm

    Accelerated junctional rhythm is when the rhythm of emerged impulses is more than 40 to 60 beats per minute, which is the natural range of the junction. It happens in some instances such as digoxin toxicity, and usually has a rate of between 60 and 100 bpm.

  7. Cardiac action potential - Wikipedia

    en.wikipedia.org/wiki/Cardiac_action_potential

    In the standard non-pacemaker cell the voltage during this phase is more or less constant, at roughly -90 mV. [11] The resting membrane potential results from the flux of ions having flowed into the cell (e.g. sodium and calcium), the flux of ions having flowed out of the cell (e.g. potassium, chloride and bicarbonate), as well as the flux of ...

  8. Ectopic beat - Wikipedia

    en.wikipedia.org/wiki/Ectopic_beat

    Ectopic beat is a disturbance of the cardiac rhythm frequently related to the electrical conduction system of the heart, in which beats arise from fibers or group of fibers outside the region in the heart muscle ordinarily responsible for impulse formation (i.e., the sinoatrial node).

  9. Atrial tachycardia - Wikipedia

    en.wikipedia.org/wiki/Atrial_tachycardia

    Atrial tachycardia is a type of heart rhythm problem in which the heart's electrical impulse comes from an ectopic pacemaker (that is, an abnormally located cardiac pacemaker) in the upper chambers of the heart, rather than from the sinoatrial node, the normal origin of the heart's electrical activity.