Each Holter system has hardware (called monitor or recorder) for recording the signal, and software for review and analysis of the record. There may be a "patient button" on the front that the patient can press at specific instants such as feeling/being sick, going to bed, taking pills, marking an event of symptoms which is then documented in the symptoms diary, etc.; this records a mark that ...
Cardiac monitoring generally refers to continuous or intermittent monitoring of heart activity to assess a patient's condition relative to their cardiac rhythm. Cardiac monitoring is usually carried out using electrocardiography , which is a noninvasive process that records the heart's electrical activity and displays it in an electrocardiogram ...
A standard 12-lead ECG report (an electrocardiograph) shows a 2.5 second tracing of each of the twelve leads. The tracings are most commonly arranged in a grid of four columns and three rows. The first column is the limb leads (I, II, and III), the second column is the augmented limb leads (aVR, aVL, and aVF), and the last two columns are the ...
Cardiac monitoring, which generally refers to continuous electrocardiography with assessment of the patient's condition relative to their cardiac rhythm. A small monitor worn by an ambulatory patient for this purpose is known as a Holter monitor. Cardiac monitoring can also involve cardiac output monitoring via an invasive Swan-Ganz catheter ...
A Lewis Lead (also called the S5 lead) is a modified ECG lead used to detect atrial flutter waves when atrial flutter is suspected clinically, based on signs and symptoms, but is not definitely demonstrated on the standard 12 lead ECG. In order to create the Lewis Lead, the right arm electrode is moved to the manubrium adjacent to the sternum ...
The Modified Bruce protocol starts at a lower workload than the standard test and is typically used for elderly or sedentary patients. The first two stages of the Modified Bruce Test are performed at a 1.7 mph and 0% grade and 1.7 mph and 5% grade, and the third stage corresponds to the first stage of the Standard Bruce Test protocol as listed ...
The ILR is a useful diagnostic tool to investigate patients who experience symptoms such as syncope (fainting), seizures, recurrent palpitations, lightheadedness, or dizziness not often enough to be captured by a 24-hour or 30-day external monitor. Because of the ILR's long battery life (up to 3 years), the heart can be monitored for an ...
Cardiac stress testing is used to determine to assess cardiac function and to disclose evidence of exertion-related cardiac hypoxia. Radionuclide testing using thallium or technetium can be used to demonstrate areas of perfusion abnormalities. With a maximal stress test the level of exercise is increased until the person's heart rate will not ...