  2. Vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Vacuum_breaker

    Vacuum breakers can be used in sewage applications as an alternative to a water seal. It utilizes a one-way membrane that acts similar to a check valve. The membrane is sensitive enough to open under the weight of four ounces of water but remains closed when no water is present above to minimize evaporation and eliminate sewer gas odors. [4]

  3. Reduced pressure zone device - Wikipedia

    en.wikipedia.org/wiki/Reduced_pressure_zone_device

    Because certain combinations of check valve failure and/or system backpressure cause the relief valve to discharge, the device must be mounted in a location where the drain will not become flooded. An example of where backflow would harm the water supply is the use of well washing devices inside underground sewerage pumping stations.

  4. Pressure vacuum breaker - Wikipedia

    en.wikipedia.org/wiki/Pressure_vacuum_breaker

    A pressure vacuum breaker (PVB) is a type of backflow prevention device, used to keep non-potable (or contaminated) water from entering the water supply. A PVB is similar to an atmospheric vacuum breaker (AVB), except that the PVB contains a spring-loaded poppet. This makes it acceptable for applications that are high hazard or where valves are ...

  5. Water heat recycling - Wikipedia

    en.wikipedia.org/wiki/Water_heat_recycling

    Installation of a double-walled copper-on-copper heat exchanger in a vertical section of the master drain line in a Canadian home (2007) Water heat recycling (also known as drain water heat recovery, waste water heat recovery, greywater heat recovery, [citation needed] or sometimes shower water heat recovery [citation needed]) is the use of a heat exchanger to recover energy and reuse heat ...

  6. Backflow prevention device - Wikipedia

    en.wikipedia.org/wiki/Backflow_prevention_device

    Backflow prevention device. The simplest, most reliable way to provide backflow prevention is to provide an air gap.An air gap is simply an open vertical space between any device that connects to a plumbing system (like a valve or faucet) and any place where contaminated water can collect or pool.

  7. Backflow - Wikipedia

    en.wikipedia.org/wiki/Backflow

    Backwater sanitary valves (also known as "check valves" or "backwater valves") are also often referred to as "backflow preventers" [4] [5] They are intended to prevent backflow of sewage on the sanitary sewer line during a flood or sewer blockage, and have no connection with potable water. Also sewage lifting stations provide comprehensive ...