enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Neurological pupil index - Wikipedia

    en.wikipedia.org/wiki/Neurological_Pupil_Index

    The Neurological Pupil index, or NPi, is an algorithm developed by NeurOptics, Inc., that removes subjectivity from the pupillary evaluation. A patient's pupil measurement (including variables such as size, latency, constriction velocity, dilation velocity, etc.) is obtained using a pupillometer, and the measurement is compared against a normative model of pupil reaction to light and ...

  3. Pupillometry - Wikipedia

    en.wikipedia.org/wiki/Pupillometry

    The more difficult the task, the greater pupil diameter observed from the time preceding the solution [50] until the task was completed. [51] While these discoveries from the 1960s sparked renewed interest in the psychological significance of pupil size, research had substantially earlier identified the relationship between pupil size and effort.

  4. Cranial nerve examination - Wikipedia

    en.wikipedia.org/wiki/Cranial_nerve_examination

    The pupil size is measured, its shape and any asymmetry is tested. A commonly used abbreviation to describe normal pupils is PERRLA (pupils equal, round and reactive to light and accommodation). Pupillary light reflex is tested by having the patient stare into the distance as the examiner shines the penlight obliquely into each pupil. Pupillary ...

  5. Pupilometer - Wikipedia

    en.wikipedia.org/wiki/Pupilometer

    Pupil data can be uploaded to the patient record, eliminating the possibility of data entry errors. The pupil size and reactivity are daily measurements and part of the protocol for critically injured or ill patients. They are essential in the clinical monitoring and neurological assessment of the patient.

  6. Pupillary light reflex - Wikipedia

    en.wikipedia.org/wiki/Pupillary_light_reflex

    By analogy with a camera, the pupil is equivalent to aperture, whereas the iris is equivalent to the diaphragm. It may be helpful to consider the Pupillary reflex as an 'Iris' reflex, as the iris sphincter and dilator muscles are what can be seen responding to ambient light. [2] Whereas, the pupil is the passive opening formed by the active iris.

  7. List of optometric abbreviations - Wikipedia

    en.wikipedia.org/wiki/List_of_optometric...

    Visual acuity with Near chart without correctors Visual acuity with eye chart at Near 15.7 inches (400 mm) and without (sc: Latin sine correctore) correctors (spectacles); Ncc is with (cc: Latin cum correctore) correctors. See Visual_acuity#Legal_definitions: VA OS Left visual acuity VA OD Right visual acuity VDU Visual display unit VF Visual field

  8. Swinging light test - Wikipedia

    en.wikipedia.org/wiki/Swinging_light_test

    For an adequate test, vision must not be entirely lost. In dim room light, the examiner notes the size of the pupils. The patient is asked to gaze into the distance, and the examiner swings the beam of a penlight back and forth from one pupil to the other, and observes the size of pupils and reaction in the eye that is lit.

  9. Humphrey visual field analyser - Wikipedia

    en.wikipedia.org/wiki/Humphrey_Visual_Field_Analyser

    Used for macula, retinal and neuro-ophthalmic conditions and advanced glaucoma [4] 24-2: Measures 24 degrees temporally and 30 degrees nasally and tests 54 points. Used for neuro-ophthalmic conditions and general screening [5] as well as early detection of glaucoma [6] [7] 30-2: Measures 30 degrees temporally and nasally and tests 76 points.