A generator interlock kit (or a transfer switch), eliminates the need for extension cords to power appliances. [2]Like a transfer switch, an interlock kit lets the generator energize the panel and all of its circuits (up to the load capacity of the generator); not just corded appliances.
Stand-alone switched-mode power supply An adjustable switched-mode power supply for laboratory use. A switched-mode power supply (SMPS), also called switching-mode power supply, switch-mode power supply, switched power supply, or simply switcher, is an electronic power supply that incorporates a switching regulator to convert electrical power efficiently.
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t
High power LED current (peak 2.7 A) [5] 5 A One typical 12 V motor vehicle headlight (typically 60 W) 9 A 230 V AC, toaster, kettle (2 kW) 10 1: 10 or 20 A 230 V AC, Europe common domestic circuit breaker rating 15 or 20 A 120 V AC, United States, Canada and Mexico domestic circuit breaker rating 16.6 A 120 V AC, toaster, kettle (2 kW) 20 A
Single-pole circuit breakers feed 120 V circuits from one of the 120 V buses within the panel, or two-pole circuit breakers feed 240-volt circuits from both buses. 120 V circuits are the most common, and used to power NEMA 1 and NEMA 5 outlets, and most residential and light commercial direct-wired lighting circuits.
A common prefixed derived unit is "kilovolt-ampere" (symbol kVA). The VA rating is limited by the maximum permissible current, and the watt rating by the power-handling capacity of the device. When a UPS powers equipment which presents a reactive load with a low power factor, neither limit may safely be exceeded. [5]
A 10-outlet rack-mount PDU (front), connected to a UPS (bottom unit on right) A temporary PDU, distributing 120 volt AC power at an outdoor event Cabinet PDU with access doors open A power distribution unit ( PDU ) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking ...
Primaries provide power at the standard distribution voltages used in the area; these range from as low as 2.3 kV to about 35 kV depending on local distribution practice and standards, often 11 kV (50 Hz systems) and 13.8 kV (60 Hz systems) are used, but many other voltages are standard.