enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Physics of magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Physics_of_magnetic...

    The magnet is the largest and most expensive component of the scanner, and the remainder of the scanner is built around it. The strength of the magnet is measured in teslas (T). Clinical magnets generally have a field strength in the range 0.1–3.0 T, with research systems available up to 9.4 T for human use and 21 T for animal systems. [42]

  3. Orders of magnitude (magnetic field) - Wikipedia

    en.wikipedia.org/wiki/Orders_of_magnitude...

    Magnetic induction B (also known as magnetic flux density) has the SI unit tesla [T or Wb/m 2]. [1] One tesla is equal to 10 4 gauss. Magnetic field drops off as the inverse cube of the distance (⁠ 1 / distance 3 ⁠) from a dipole source. Energy required to produce laboratory magnetic fields increases with the square of magnetic field. [2]

  4. Gauss (unit) - Wikipedia

    en.wikipedia.org/wiki/Gauss_(unit)

    10 −6 –10 −3 G – the magnetic field of Galactic molecular clouds. Typical magnetic field strengths within the interstellar medium of the Milky Way are ~5 μG. 0.25–0.60 G – the Earth's magnetic field at its surface; 4 G – near Jupiter's equator; 25 G – the Earth's magnetic field in its core [4] 50 G – a typical refrigerator magnet

  5. Magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Magnetic_resonance_imaging

    The field strength of the magnet is measured in teslas – and while the majority of systems operate at 1.5 T, commercial systems are available between 0.2 and 7 T. 3T MRI systems, also called 3 Tesla MRIs, have stronger magnets than 1.5 systems and are considered better for images of organs and soft tissue. [7]

  6. Magnetic refrigeration - Wikipedia

    en.wikipedia.org/wiki/Magnetic_refrigeration

    Refrigerators based on the magnetocaloric effect have been demonstrated in laboratories, using magnetic fields starting at 0.6 T up to 10 T. Magnetic fields above 2 T are difficult to produce with permanent magnets and are produced by a superconducting magnet (1 T is about 20.000 times the Earth's magnetic field).

  7. Tesla (unit) - Wikipedia

    en.wikipedia.org/wiki/Tesla_(unit)

    1.5 T to 3 T – strength of medical magnetic resonance imaging systems in practice, experimentally up to 17 T [10] 4 T – strength of the superconducting magnet built around the CMS detector at CERN [11] 5.16 T – the strength of a specially designed room temperature Halbach array [12] 8 T – the strength of LHC magnets; 11.75 T – the ...

  8. Portable magnetic resonance imaging - Wikipedia

    en.wikipedia.org/wiki/Portable_magnetic...

    Portable magnetic resonance imaging (MRI) is referred to the imaging provided by an MRI scanner that has mobility and portability. [1] [2] [3] It provides MR imaging to the patient in-time and on-site, for example, in intensive care unit (ICU) where there is danger associated with moving the patient, in an ambulance, after a disaster rescue, or in a field hospital/medical tent.

  9. Scanning SQUID microscopy - Wikipedia

    en.wikipedia.org/wiki/Scanning_SQUID_microscopy

    The strength of the field being measured will then be equal to the strength of the bias magnetic field passing through the SQUID. Although it is possible to read the DC voltage between the two terminals of the SQUID directly, because noise tends to be a problem in DC measurements, an alternating current technique is used.