  2. Hexaxial reference system - Wikipedia

    en.wikipedia.org/wiki/Hexaxial_reference_system

    The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...

  3. Electrocardiography - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography

    The 12-lead ECG has a total of three limb leads and three augmented limb leads arranged like spokes of a wheel in the coronal plane (vertical), and six precordial leads or chest leads that lie on the perpendicular transverse plane (horizontal). [33] Leads should be placed in standard positions.

  4. Diagnosis of myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Diagnosis_of_myocardial...

    The standard 12 lead ECG does not directly examine the right ventricle, and is relatively poor at examining the posterior basal and lateral walls of the left ventricle. In particular, acute myocardial infarction in the distribution of the circumflex artery is likely to produce a nondiagnostic ECG. [ 10 ]

  5. Electrocardiography in myocardial infarction - Wikipedia

    en.wikipedia.org/wiki/Electrocardiography_in...

    The 2018 European Society of Cardiology/American College of Cardiology Foundation/American Heart Association/World Health Federation Universal Definition of Myocardial Infarction for the ECG diagnosis of the ST segment elevation type of acute myocardial infarction require new ST elevation at J point of at least 1mm (0.1 mV) in two contiguous leads with the cut-points: ≥1 mm in all leads ...

  6. Right axis deviation - Wikipedia

    en.wikipedia.org/wiki/Right_axis_deviation

    This refers to the appearance of leads I and II. If the QRS complex is negative in lead I and positive in lead II, the QRS complexes appear to be "reaching" to touch each other. This signifies right axis deviation. Conversely, if the QRS complex is positive in lead I and negative in lead II the leads have the appearance of "leaving" each other.

  7. Sinus rhythm - Wikipedia

    en.wikipedia.org/wiki/Sinus_rhythm

    any of biphasic (–/+), positive or negative in lead aVL; positive in all chest leads, except for V1 which may be biphasic (+/–) [2] If the P waves do not meet these criteria, they must be originating from an abnormal site elsewhere in the atria and not from the sinus node; the ECG cannot, therefore, be classed as showing a sinus rhythm. [2]

  8. Rhythm interpretation - Wikipedia

    en.wikipedia.org/wiki/Rhythm_interpretation

    Ventricular tachycardia is a regular rhythm with a rate of 140-250 bpm, there are no P waves and the main feature is a wide QRS complex (0.12 and greater) Ventricular fibrillation has no p waves or QRS complexes, there are only wavy irregular deflections throughout the heart rhythm, at this point the heart would have a rate of 0 and be ...

  9. Ventricular fibrillation - Wikipedia

    en.wikipedia.org/wiki/Ventricular_fibrillation

    In clinical practice, therefore, factors that would lead to the right conditions to favour such re-entry mechanisms include increased heart size through hypertrophy or dilatation, drugs which alter the length of the refractory period and areas of cardiac disease. Therefore, the substrate of ventricular fibrillation is transient or permanent ...