enow.com Web Search

Search results

  1. Results from the WOW.Com Content Network
  2. Vernier scale - Wikipedia

    en.wikipedia.org/wiki/Vernier_scale

    So for a vernier with a constant of 0.1, each mark on the vernier is spaced 9/10 of those on the main scale. If you put the two scales together with zero points aligned, the first mark on the vernier scale is 1/10 short of the first main scale mark, the second is 2/10 short, and so on up to the ninth mark, which is misaligned by 9/10.

  3. Measurement microphone calibration - Wikipedia

    en.wikipedia.org/wiki/Measurement_microphone...

    Free field reciprocity calibration (to give the free-field response, as opposed to the pressure response of the microphone) follows the same principles and roughly the same method as pressure reciprocity calibration, but in practice is much more difficult to implement. As such it is more usual to perform reciprocity calibration in an acoustical ...

  4. Mitutoyo - Wikipedia

    en.wikipedia.org/wiki/Mitutoyo

    Mitutoyo America Corporation was formed in 1963 and is headquartered in Aurora, Illinois (just outside Chicago).Mitutoyo America offers the full product line of precision measuring tools, instruments and equipment with a distribution network, training and education classes, software development, and service support to provide a comprehensive metrology organization.

  5. Calipers - Wikipedia

    en.wikipedia.org/wiki/Calipers

    Caliper is the American spelling, while calliper (double "L") is the British spelling. A single tool might be referred to as a caliper or as calipers — a plural only (plurale tantum) form, like scissors or glasses. Colloquially, the phrase "pair of verniers" or just "vernier" might refer to a vernier caliper.

  6. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    The formal definition of calibration by the International Bureau of Weights and Measures (BIPM) is the following: "Operation that, under specified conditions, in a first step, establishes a relation between the quantity values with measurement uncertainties provided by measurement standards and corresponding indications with associated measurement uncertainties (of the calibrated instrument or ...

  7. Caliper log - Wikipedia

    en.wikipedia.org/wiki/Caliper_log

    A caliper log is a well logging tool that provides a continuous measurement of the size and shape of a borehole along its depth [1] and is commonly used in hydrocarbon exploration. The measurements that are recorded can be an important indicator of wash-outs, cave ins or shale swelling in the borehole, which can affect the results of other well ...

  8. Micrometer (device) - Wikipedia

    en.wikipedia.org/wiki/Micrometer_(device)

    Commercial machine shops, especially those that do certain categories of work (military or commercial aerospace, nuclear power industry, medical, and others), are required by various standards organizations (such as ISO, ANSI, ASME, [19] ASTM, SAE, AIA, the U.S. military, and others) to calibrate micrometers and other gauges on a schedule ...

  9. Calibration curve - Wikipedia

    en.wikipedia.org/wiki/Calibration_curve

    A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]