  1. Results from the WOW.Com Content Network
  2. Current limiting - Wikipedia

    en.wikipedia.org/wiki/Current_limiting

    An inrush current limiter is a device or devices combination used to limit inrush current. Passive resistive components such as resistors (with power dissipation drawback), or negative temperature coefficient (NTC) thermistors are simple options while the positive one (PTC) is used to limit max current afterward as the circuit has been operating (with cool-down time drawback on both).

  3. Series and parallel circuits - Wikipedia

    en.wikipedia.org/wiki/Series_and_parallel_circuits

    Many circuits can be analyzed as a combination of series and parallel circuits, along with other configurations. In a series circuit, the current that flows through each of the components is the same, and the voltage across the circuit is the sum of the individual voltage drops across each component. [1]

  4. Network analysis (electrical circuits) - Wikipedia

    en.wikipedia.org/wiki/Network_analysis...

    These two networks are equivalent and the transformations between them are given below. A general network with an arbitrary number of nodes cannot be reduced to the minimum number of impedances using only series and parallel combinations. In general, Y-Δ and Δ-Y transformations must also be used.

  5. Fault current limiter - Wikipedia

    en.wikipedia.org/wiki/Fault_current_limiter

    A fault current limiter (FCL), also known as fault current controller (FCC), [1] is a device which limits the prospective fault current when a fault occurs (e.g. in a power transmission network) without complete disconnection. The term includes superconducting, solid-state and inductive devices. [2]

  6. Current divider - Wikipedia

    en.wikipedia.org/wiki/Current_divider

    Instead of using impedances, the current divider rule can be applied just like the voltage divider rule if admittance (the inverse of impedance) is used: =. Take care to note that Y T is a straightforward addition, not the sum of the inverses inverted (as would be done for a standard parallel resistive network).

  7. Electrical isolation test - Wikipedia

    en.wikipedia.org/wiki/Electrical_isolation_test

    A minimum acceptable resistance value is usually specified (typically in the mega ohm (MΩ) range per circuit tested). Multiple circuits having a common return may be tested simultaneously, provided the minimum allowable resistance value is based on the number of circuits in parallel. Five basic isolation test configurations exist: [3] Single ...

  8. Constant-current diode - Wikipedia

    en.wikipedia.org/wiki/Constant-current_diode

    It is known as a current-limiting diode (CLD) or current-regulating diode (CRD). Internal structure. It consists of an n-channel JFET with the gate shorted to the source, which functions like a two-terminal current limiter (analogous to a voltage-limiting Zener diode). It allows a current through it to rise to a certain value, but not higher.

  9. IEC 61000-4-5 - Wikipedia

    en.wikipedia.org/wiki/IEC_61000-4-5

    The surge is defined by the Combination Wave Generator's open-circuit voltage and short-circuit current waveforms, characterized by front time, duration, and peak values. With an open circuit output, the surge voltage is a double exponential pulse in the form of k ( e − α t − e − β t ) {\displaystyle k(e^{-\alpha t}-e^{-\beta t})} .