An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning system. [1] An air handler is usually a large metal box containing a blower , furnace or A/C elements, filter racks or chambers, sound attenuators , and dampers . [ 2 ]
DOAS air handling unit with heat recovery wheel and passive dehumidification. A dedicated outdoor air system (DOAS) is a type of heating, ventilation and air-conditioning system that consists of two parallel systems: a dedicated system for delivering outdoor air ventilation that handles both the latent and sensible loads of conditioning the ventilation air, and a parallel system to handle the ...
A two-stage air conditioner is designed to operate on high and low settings during different weather conditions and seasons. The high setting is used during extreme weather, and the low setting is used during moderate weather. This type of air conditioner produces a balanced temperature and is in use for a longer period of time.
An air handling unit used for the heating and cooling air: (1) supply air (2) fan section (3) vibration isolator (4) cooling coil (5) filter (6) mixed air duct. Air supply to a building is generally performed by an air handling unit. The process may include filtering, heating, cooling, humidification, or dehumidification, all of which consume ...
The air blower's flow rate is variable. For a single VAV air handler that serves multiple thermal zones, the flow rate to each zone must be varied as well. Simple VAV terminal unit. A VAV terminal unit, [9] often called a VAV box, is the zone-level flow control device. It is basically a calibrated air damper with an automatic actuator. The VAV ...
Displacement ventilation is best suited for taller spaces (higher than 3 meters [10 feet]). [2] Standard mixing ventilation may be better suited for smaller spaces where air quality is not as great a concern, such as single-occupant offices, and where the room height is not tall (e.g., lower than 2.3 meters [7.5 feet]).
Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. [1] Similar to ductless mini-split systems, VRFs use refrigerant as the primary cooling and heating medium, and are usually less complex than conventional chiller-based systems.
Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...