    A typical evaporative, forced draft open-loop cooling tower rejecting heat from the condenser water loop of an industrial chiller unit Natural draft wet cooling hyperboloid towers at Didcot Power Station (UK) Forced draft wet cooling towers (height: 34 meters) and natural draft wet cooling tower (height: 122 meters) in Westphalia, Germany Natural draft wet cooling tower in Dresden (Germany)

  3. Chiller - Wikipedia

    en.wikipedia.org/wiki/Chiller

    A liquid (glycol based) chiller with an air cooled condenser on the rooftop of a medium size commercial building. In air conditioning systems, chilled coolant, usually chilled water mixed with ethylene glycol, from a chiller in an air conditioning or cooling plant is typically distributed to heat exchangers, or coils, in air handlers or other types of terminal devices which cool the air in ...

  4. Chilled water - Wikipedia

    en.wikipedia.org/wiki/Chilled_water

    The cooling towers of a large chilled water system. As part of a chilled water system, the condenser water absorbs heat from the refrigerant in the condenser barrel of the water chiller and is then sent via return lines to a cooling tower, which is a heat exchange device used to transfer waste heat to the atmosphere.

  5. Free cooling - Wikipedia

    en.wikipedia.org/wiki/Free_cooling

    The cooling tower water can be directly linked into the flow through the chilled water circuit. If the cooling tower is open then a strainer is required to eliminate any debris that could accumulate within the tower. The cost savings are associated with the limited use of the water chiller energy. There is an increased risk of corrosion using ...

  6. District cooling - Wikipedia

    en.wikipedia.org/wiki/District_cooling

    District cooling is the cooling equivalent of district heating. Working on principles broadly similar to district heating, district cooling delivers chilled water to buildings like offices and factories. In winter, the source for cooling can often be seawater, so it is a cheaper resource than electricity to run compressors for cooling.

  7. Chiller boiler system - Wikipedia

    en.wikipedia.org/wiki/Chiller_boiler_system

    A chiller boiler system is a hydronic system. It uses water instead of air to heat and cool a structure. A properly designed hydronic system is usually more efficient than a standard forced air system. [1] Chiller boiler systems use radiant heating and cooling or fan coil systems to condition a home or business. This allows for multiple zones ...

  8. Cascade refrigeration - Wikipedia

    en.wikipedia.org/wiki/Cascade_refrigeration

    A two-cycle cascade refrigeration process schematic diagram. A cascade refrigeration cycle is a multi-stage thermodynamic cycle. An example two-stage process is shown at right. (Bottom on mobile) The cascade cycle is often employed for devices such as ULT freezers. [1]

  9. Cryocooler - Wikipedia

    en.wikipedia.org/wiki/Cryocooler

    Fig.5 Schematic diagram of a GM-cooler. V l and V h are buffer volumes of the compressor. The compression heat is removed by the cooling water of the compressor via a heat exchanger. The rotary valves alternatingly connect the cooler to the high- and the low-pressure sides of the compressor and runs synchronous with the displacer.