Thermodynamic heat pump cycles or refrigeration cycles are the conceptual and mathematical models for heat pump, air conditioning and refrigeration systems. [1] A heat pump is a mechanical system that transmits heat from one location (the "source") at a certain temperature to another location (the "sink" or "heat sink") at a higher temperature. [2]
A DuPont R-134a refrigerant. A refrigerant is a working fluid used in cooling, heating or reverse cooling and heating of air conditioning systems and heat pumps where they undergo a repeated phase transition from a liquid to a gas and back again.
A condenser unit used in central air conditioning systems typically has a heat exchanger section to cool down and condense incoming refrigerant vapor into liquid, a compressor to raise the pressure of the refrigerant and move it along, and a fan for blowing outside air through the heat exchanger section to cool the refrigerant inside. A typical ...
When combining a passive daytime radiative cooling system with thermal insulation and evaporative cooling, one study found a 300% increase in ambient cooling power when compared to a stand-alone radiative cooling surface, which could extend the shelf life of food by 40% in humid climates and 200% in desert climates without refrigeration. The ...
A representative pressure–volume diagram for a refrigeration cycle. Vapour-compression refrigeration or vapor-compression refrigeration system (VCRS), [1] in which the refrigerant undergoes phase changes, is one of the many refrigeration cycles and is the most widely used method for air conditioning of buildings and automobiles.
Common absorption refrigerators use a refrigerant with a very low boiling point (less than −18 °C (0 °F)) just like compressor refrigerators.Compression refrigerators typically use an HCFC or HFC, while absorption refrigerators typically use ammonia or water and need at least a second fluid able to absorb the coolant, the absorbent, respectively water (for ammonia) or brine (for water).
Outside air at ambient temperature and pressure is used as the coolant in this air-to-air heat exchanger. Once the hot air has been cooled, it is then compressed by the centrifugal compressor. This compression heats the air (the maximum air temperature at this point is about 250 °C) and it is sent to the secondary heat exchanger, which again ...
There, the hot refrigerant gas condenses back to a liquid and transfers the stored latent heat to the indoor air, water heating or hot water system. The indoor air or heating water is pumped across the heat exchanger by an electric pump or fan. The cool liquid refrigerant then re-enters the outdoor heat exchanger coils to begin a new cycle.