A blood gas test or blood gas analysis tests blood to measure blood gas tension values and blood pH.It also measures the level and base excess of bicarbonate.The source of the blood is reflected in the name of each test; arterial blood gases come from arteries, venous blood gases come from veins and capillary blood gases come from capillaries. [1]
An arterial blood gas (ABG) test, or arterial blood gas analysis (ABGA) measures the amounts of arterial gases, such as oxygen and carbon dioxide. An ABG test requires that a small volume of blood be drawn from the radial artery with a syringe and a thin needle , [ 1 ] but sometimes the femoral artery in the groin or another site is used.
Arterial blood carbon dioxide tension. P a CO 2 – Partial pressure of carbon dioxide at sea level in arterial blood is between 35 and 45 mmHg (4.7 and 6.0 kPa). [9] Venous blood carbon dioxide tension. P v CO 2 – Partial pressure of carbon dioxide at sea level in venous blood is between 40 and 50 mmHg (5.33 and 6.67 kPa). [9]
Alveolar air includes exhaust gases such as CO 2 [2] [3] Arterial blood (PaO 2) 98-95: Oxygen must cross the alveoli, leading to a drop in PO 2 called the alveolar-to-arterial gradient (typically a drop of 1-5 mmHg, but sometimes larger). [1] [3] Venous blood (PvO 2) 40-35: Arterial blood offloads oxygen in the capillaries before flowing into ...
In addition to arterial blood gas, an anion gap can also differentiate between possible causes. The Henderson-Hasselbalch equation is useful for calculating blood pH, because blood is a buffer solution. In the clinical setting, this equation is usually used to calculate HCO 3 from measurements of pH and PaCO2 in arterial blood gases. The amount ...
For example, hemolysis, icterus, lipemia, or heterophile antibodies may confound results obtained by traditional methods such as ion-selective electrodes, enzymatic assays or immunoassays. Alternate methods such as blood gas analysers, point-of-care testing or mass spectrometry may help resolve the clinical question.
Automated coagulation machines or Coagulometers measure the ability of blood to clot by performing any of several types of tests including Partial thromboplastin times, Prothrombin times (and the calculated INRs commonly used for therapeutic evaluation), Lupus anticoagulant screens, D dimer assays, and factor assays.
The average red blood cell contains 250 million hemoglobin molecules. [7] Hemoglobin contains a globin protein unit with four prosthetic heme groups (hence the name heme-o-globin); each heme is capable of reversibly binding with one gaseous molecule (oxygen, carbon monoxide, cyanide, etc.), [8] therefore a typical red blood cell may carry up to one billion gas molecules.