Search results
Results from the WOW.Com Content Network
Pulmonary function testing is a safe procedure; however, there is cause for concern regarding untoward reactions and the value of the test data should be weighed against potential hazards. Some complications include dizziness, shortness of breath, coughing, pneumothorax, and inducing an asthma attack.
Device for spirometry. The patient places his or her lips around the blue mouthpiece. The teeth go between the nubs and the shield, and the lips go over the shield. A nose clip guarantees that breath will flow only through the mouth. Screen for spirometry readouts at right. The chamber can also be used for body plethysmography.
Perfluorocarbon tracers (PFTs) are a range of perfluorocarbons used in flow tracers and other tracing applications. They are used by releasing the PFT at a certain point, and determining the concentration of that PFT at another set of points, allowing the flow from the source to the points to be determined.
Diffusing capacity of the lung (D L) (also known as transfer factor) measures the transfer of gas from air in the lung, to the red blood cells in lung blood vessels. It is part of a comprehensive series of pulmonary function tests to determine the overall ability of the lung to transport gas into and out of the blood.
There are a number of non-equivalent scales used in the interpretation of peak expiratory flow. [4] Some examples of Reference Values are given below. There is a wide natural variation in results from healthy test subjects. Wright scale [5] [6] EN 13826 or EU scale [7] NHANESIII [8] reference values provided by the US Centers for Disease ...
A spirometer is the main piece of equipment used for basic Pulmonary Function Tests (PFTs). Lung diseases such as asthma, bronchitis, and emphysema may be ruled out from the tests. In addition, a spirometer often is used for finding the cause of shortness of breath, assessing the effect of contaminants on lung function, the effect of medication ...
An initial spirometry is performed to assess the patient's native respiratory status. The patient will be asked to take a deep breath and then blow into the mouthpiece of the spirometer as hard as you can. This is a baseline measurement.
Restrictive lung disease is characterized by reduced lung volumes, and therefore reduced lung compliance, either due to an intrinsic reason, for example a change in the lung parenchyma, or due to an extrinsic reason, for example diseases of the chest wall, pleura, or respiratory muscles. [3]