Search results
Results from the WOW.Com Content Network
In gas chromatography, the Kovats retention index (shorter Kovats index, retention index; plural retention indices) is used to convert retention times into system-independent constants. The index is named after the Hungarian-born Swiss chemist Ervin Kováts , who outlined the concept in the 1950s while performing research into the composition ...
Example chromatogram showing signal as a function of retention time. In chromatography, resolution is a measure of the separation of two peaks of different retention time t in a chromatogram. [1] [2] [3] [4]
The relative response factor is the expected ratio of an analyte to an internal standard (or external standard) and is calculated by finding the response of a known amount of analyte and a constant amount of internal standard (a chemical added to the sample at a constant concentration, with a distinct retention time to the analyte).
Pyrolysis–gas chromatography–mass spectrometry is a method of chemical analysis in which the sample is heated to decomposition to produce smaller molecules that are separated by gas chromatography and detected using mass spectrometry. Pyrolysis is the thermal decomposition of materials in an inert atmosphere or a vacuum.
A mass chromatogram is a representation of mass spectrometry data as a chromatogram, where the x-axis represents time and the y-axis represents signal intensity. [1] The source data contains mass information; however, it is not graphically represented in a mass chromatogram in favor of visualizing signal intensity versus time.
Chromatographic response function, often abbreviated to CRF, is a coefficient which measures the quality of the separation in the result of a chromatography.. The CRF concept have been created during the development of separation optimization, to compare the quality of many simulated or real chromatographic separations.
The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (e.g. Flame ionization detector) cannot differentiate between multiple molecules that happen to take the same amount of time to travel through the column (i.e. have the same retention time), which results in two or more ...
In chromatography, the retardation factor (R) is the fraction of an analyte in the mobile phase of a chromatographic system. [1] In planar chromatography in particular, the retardation factor R F is defined as the ratio of the distance traveled by the center of a spot to the distance traveled by the solvent front. [2]